SYMPTOMS
========

When you try to create a single-threaded dynamic-link library (DLL) or
multi-threaded DLL that implements the Office Add-in IDTExtensibility2
Interface, the resulting .dll file or .exe file does not contain the
IDTExtensibility2 interface.

RESOLUTION
==========

To resolve this problem, obtain the latest service pack for Visual FoxPro for
Windows 7.0. For additional information, please see the following article in the
Microsoft Knowledge Base:

  Q316964 How to Obtain the Latest Visual FoxPro for Windows 7.0 Service Pack

STATUS
======

Microsoft has confirmed this to be a problem in Microsoft Visual FoxPro for
Windows 7.0.

This problem was first corrected in Visual FoxPro for Windows 7.0 Service Pack 1.

MORE INFORMATION
================

Steps to Reproduce the Behavior
-------------------------------

On a computer with Visual FoxPro 7.0 and Microsoft Office 2000 or later
installed, follow these steps:

1. On the Tools menu, click Object Browser.

2. In the Object Browser, click Options, and then click to select all of the
  options under Display Options.

3. Close the Object Browser.

4. Paste the following code in a program (.prg) file named Test, and then run
  the program from the Command window:

  NOTE: Change the path to include Msaddndr.dll file if necessary.

  RELEASE ALL
  CLEAR ALL
  DELETE FILE testxx.*

  CREATE PROJECT testxx NOWAIT
  TEXT TO lcText NOSHOW
  x = NEWOBJECT("myclass")

  DEFINE CLASS myclass AS session OLEPUBLIC

  	IMPLEMENTS IDTExtensibility2 IN "C:\program files\common files\designer\msaddndr.dll"

  	PROCEDURE IDTExtensibility2_OnConnection(_Application AS VARIANT, ConnectMode AS VARIANT, AddInInst AS VARIANT, custom AS VARIANT) AS VOID
  	* Add user code here.
  	ENDPROC

  	PROCEDURE IDTExtensibility2_OnDisconnection(RemoveMode AS VARIANT, custom AS VARIANT) AS VOID
  	* Add user code here.
  	ENDPROC

  	PROCEDURE IDTExtensibility2_OnAddInsUpdate(custom AS VARIANT) AS VOID
  	* Add user code here.
  	ENDPROC

  	PROCEDURE IDTExtensibility2_OnStartupComplete(custom AS VARIANT) AS VOID
  	* Add user code here.
  	ENDPROC

  	PROCEDURE IDTExtensibility2_OnBeginShutdown(custom AS VARIANT) AS VOID
  	* Add user code here.
  	ENDPROC
  ENDDEFINE
  ENDTEXT

  STRTOFILE(lcText,'testxx.prg',0)
  _VFP.ACTIVEPROJECT.FILES.ADD('testxx.prg')
  _VFP.ACTIVEPROJECT.BUILD('testxx.dll',4)
  _VFP.ACTIVEPROJECT.CLOSE

  DO (_OBJECTBROWSER)
  _oobjectbrowser.loadtypelib(SET("Default")+CURDIR()+'testxx.dll')

  RETURN 

If you run the example code in Visual FoxPro 7.0, you receive the following error
message:

  An error occured loading the requested type library!
  The selected file is either invalid or not a type library.

If you try to manually build the project by using the Project Manager or by using
the BUILD command, you receive the following error message:

  Unknown error <error number>

If you run the code in Visual FoxPro 7.0 Service Pack 1, no error occurs.

To view the IDTExtensibility2 interface in Visual FoxPro 7.0 Service Pack 1,
follow these steps:

1. Expand the Classes node in the left pane of the Object Browser.

2. Select myclass, and observe that the IDTExtensibility2 interface appears in
  the right pane under Interfaces.

To clean up the registry entries for the .dll that is created in this
reproduction, follow these steps:

1. From Visual FoxPro, use the change directory (CD) command to change to the
  directory that contains Testxx.dll.

2. Paste the following code in a .prg file, and then run the program from the
  Command window:

  DECLARE INTEGER DllUnregisterServer IN TESTXX.DLL
  ? DLLUnregisterServer()
  CLEAR DLLS

A 0 appears, indicating that the registry entries for the DLL have been removed.

Additional query words:

======================================================================
Keywords          : kbCOMt kbGrpDSFox kbDSupport kbCodeSnippet kbvfp700 _IK283 kbVFP700sp1fix 
Technology        : kbVFPsearch kbAudDeveloper kbVFP700
Version           : :7.0
Issue type        : kbbug
Solution Type     : kbfix

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.