KnowledgeBase Archive

An Archive of Early Microsoft KnowledgeBase Articles

View on GitHub

Q310901: HOW TO: Use Project Hook to Recycle IIS to Rebuild VFP COM DLL

Article: Q310901
Product(s): Microsoft FoxPro
Version(s): 4.0,5.0,6.0,7.0
Operating System(s): 
Keyword(s): kbAPI kbCOMt kbvfp600 kbGrpDSFox kbDSupport kbCodeSnippet kbvfp700 kbHOWTOmaster
Last Modified: 06-AUG-2002

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Visual FoxPro for Windows, versions 6.0, 7.0 
- Microsoft Internet Information Server versions 4.0, 5.0, used with:
   - the operating system: Microsoft Windows NT 4.0 
   - the operating system: Microsoft Windows 2000 
-------------------------------------------------------------------------------


IN THIS TASK
------------

- SUMMARY

   - Use a Project Hook to Recycle IIS So That VFP COM DLL Can Be Rebuilt

- REFERENCES

SUMMARY
=======

This step-by-step article demonstrates how to release a Visual FoxPro (VFP) COM
DLL that is in use by Microsoft Internet Information Server (IIS) so that it may
be rebuilt.

By default, IIS does not immediately free dynamic-link libraries (DLLs) after it
is finished with them. This provides the benefit of increased performance
because the libraries are not read from disk with each request. The libraries
are eventually freed, but if you are in the process of developing a VFP DLL for
use with IIS, you will probably not want to wait to overwrite it. To avoid this
problem, it is possible to cycle IIS from VFP (thereby freeing your COM DLL)
when you rebuild your VFP project.

Visual FoxPro 6.0 and 7.0 include the ability to execute code from the Project
Manager by using a project hook. Specifically, you can use the BeforeBuild()
event to execute code that will cycle the IIS service on the local (development)
computer, thereby freeing any used DLLs and allowing them to be overwritten.

Use a Project Hook to Recycle IIS So That VFP COM DLL Can Be Rebuilt
--------------------------------------------------------------------

1. Open Visual FoxPro 6.0 or 7.0.

2. On the File menu, click New, and then click Class.

3. Fill in the New Class dialog as follows:

  Class name: IISDLL_HOOK
  Based on: ProjectHook
  Store in: <Path>\IISDLL_HOOK.VCX (where Path is a directory path of your
  choosing on your local computer)

4. In the Class Designer, double-click the class to open the code window, and
  then select BeforeBuild from the procedure drop-down box.

5. Paste the following code in the code window below the "PARAMETERS..."
  statement.

  NOTE: This code relies on IIS being installed on the same computer as Visual
  FoxPro. The code will not work with Microsoft Personal Web Server. If you are
  using Windows 2000 or later, make sure that the Windows\System32 directory is
  in the system path. To check this, run IISRESET from a command prompt; if it
  runs successfully, the following project hook code will work as well.

  LPARAMETERS cOutputName, nBuildAction, lRebuildAll, lShowErrors, lBuildNewGuids
  *-----------------------------------
  * AUTHOR:    Trevor Hancock (trevorh@Microsoft.com)
  * CREATED:   Thursday, Oct. 18, 2001
  * ABSTRACT: This code will cycle IIS on the LOCAL machine running
  *                 Windows NT, Windows 2000, XP or .NET Server,
  *                 thereby freeing any used VFP COM DLLs allowing
  *                 them to be rebuilt. This code does NOT work with
  *                 Microsoft Personal Web Server. 
  *-----------------------------------
  #DEFINE MB_YESNO                 4   && Yes and No buttons
  #DEFINE MB_ICONQUESTION    32   && Warning query
  #DEFINE IDYES                       6   && Yes button pressed

  *!* Ask developer if Web server should be cycled.
  LOCAL lnCycleAnswer AS INTEGER
  lnCycleAnswer = MESSAGEBOX( ;
  	"Would you like cycle IIS before building?", ;
  	MB_YESNO + MB_ICONQUESTION, "Cycle Web Server?")
  IF lnCycleAnswer # IDYES
  *!* Exit: they answered "No".
  	RETURN .F.
  ENDIF

  WAIT WINDOW "Resetting IIS to free used DLL(s)..." NOWAIT NOCLEAR

  IF ("5.01" $ OS()) OR ("5.00" $ OS()) &&W2K or WXP/.NET
  	RUN IISRESET
  ELSE
  	RUN NET STOP IISADMIN /Y
  	RUN NET START W3SVC
  ENDIF

  WAIT CLEAR
  WAIT WINDOW "Reset complete. Building..." NOWAIT
   

6. Save the class and then close the Class Designer.

When you attach this project hook to a project, each time the project is built
you will be prompted to cycle the IIS server on the local computer. If you
choose to do so, any VFP COM DLLs will be freed, allowing them to be rebuilt.

REFERENCES
==========

For additional information about programmatically restarting IIS running on a
remote computer, click the article number below to view the article in the
Microsoft Knowledge Base:

  Q247557 IIS: How to Restart IIS Services by Using WSH with ADSI

Additional query words:

======================================================================
Keywords          : kbAPI kbCOMt kbvfp600 kbGrpDSFox kbDSupport kbCodeSnippet kbvfp700 kbHOWTOmaster 
Technology        : kbVFPsearch kbiisSearch kbAudDeveloper
Version           : :4.0,5.0,6.0,7.0
Issue type        : kbhowto

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.