Q276364: LU-LU Test Fails with Active AS/400 Connection

Article: Q276364
Product(s): Microsoft SNA Server
Version(s): 4.0,4.0 SP1,4.0 SP2,4.0 SP3
Operating System(s): 
Keyword(s): kbDSupport sna4 kbsna400sp1 kbsna400sp2 kbsna400sp3
Last Modified: 12-JUN-2001

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft SNA Server, versions 4.0, 4.0 SP1, 4.0 SP2, 4.0 SP3 
-------------------------------------------------------------------------------

SYMPTOMS
========

When a Microsoft SNA Server operator has an active connection to an AS/400 and
then attempts to verify LU 6.2 session availability for a given Advanced
Program-to-Program Communications (APPC) triplet (for example local LU, remote
LU, and mode name) by using the APPC Session Viewer utility, and the test fails,
look for the following event in the Microsoft Windows NT Application Event log:

  event id 18

  APPC session activation failure: BIND negative response or UNBIND request
  received

  Sense data = 80040000 (NOTE: 0032xxxx indicates UNBIND received)
  Connection = connection
  LU alias = lu alias
  PLU alias = plu alias
  Mode name = mode name

CAUSE
=====

SNA Server sent a BIND request to start an LU version 6.2 session with the
remote system, but the remote system rejected the request for the reason
indicated in the sense data error. This error is usually caused by a mismatch
between the SNA Server configuration and the configuration of the remote system
(for example, the Local APPC LU name, Remote APPC LU name or mode name specified
in the SNA BIND request may not be configured on the host).

RESOLUTION
==========

Make certain that the "Remote APPC LU" name that is created on the SNA server
matches the "Local Control Point Name" on the AS/400.

For additional information and configuration examples that show how SNA Server
can be configured to communicate with an AS/400, click the article numbers below
to view the articles in the Microsoft Knowledge Base:

  Q112158 Configuring SNA Server to Talk to AS/400 Over 802.2

  Q112159 Configuring SNA Server to Talk to AS/400 Over SDLC

Additional query words:

======================================================================
Keywords          : kbDSupport sna4 kbsna400sp1 kbsna400sp2 kbsna400sp3 
Technology        : kbAudDeveloper kbSNAServSearch kbSNAServ400 kbSNAServ400SP1 kbSNAServ400SP2 kbSNAServ400SP3
Version           : :4.0,4.0 SP1,4.0 SP2,4.0 SP3

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.