SYMPTOMS
========

After you delete a custom group class using the DelGrp.exe tool, the Dataloader
is unable to load a Management Information File (MIF) that contains changed
attributes for the same group class.

When this occurs, the information from the updated MIF does not appear in the
Administrators Console.

CAUSE
=====

This issue can occur because the DelGrp.exe tool does not delete the stored
procedures associated with the group class.

WORKAROUND
==========

To work around this issue after you run the DelGrp.exe tool to delete the Group
Class, manually delete the two stored procedures associated with the Group Class
that you deleted.

For example:

If you are deleting a group called User_info_DATA, you need to delete the stored
procedures dUser_info_DATA and pUser_info_DATA.

For information about how to delete a stored procedure, view the books online for
SQL Server. For SQL 6.5, query on "Drop Procedure". For SQL 7.0, search on "How
to delete a stored procedure".

If you are planning on adding the custom group class back after making
modifications to the smsdef.mof that deviate from the original modification,
then you may need to follow the additional items below to remove the
architecture. Otherwise, when the new architecture is created, there may be 2
references created in Resource Explorer; one containing the original
architecture that will not be displaying any data, the other with the new
architecture that does display the new data. Because the same group class name
was used, Delgrp.exe will delete BOTH objects.

1. Make a backup of the SMS server, using the native SMS backup task.

2. Make sure unwanted MIF files are removed from all client machines. (NOIDMIFS
  directory)

3. Use DELGRP.exe (part of BORK 4.5 in the SMS section) to remove the unwanted
  tables from SQL server.

4. Through SQL Enterprise Manager, manually removed the associated Stored
  Procedures, prefixed by 'p' and 'd'. (right click and delete) This is per the
  workaround in Q256073.

5. Run CONV20.exe (This will look at the SMS database and verify/repair its
  structure.)

6. Stop the WMI service.

7. Delete all files located in the c:\winnt\system32\wbem\repository directory.

8. Restart the WMI service.

STATUS
======

Microsoft has confirmed that this is a problem in the Microsoft products that
are listed at the beginning of this article.

MORE INFORMATION
================

When Dataloader processes a new MIF that contains information for the deleted
Group Class name and you have changed the format of the data, the tables for the
group class are created again but the associated stored procedures are not. The
earlier stored procedures still exist.

The stored procedures become out of sync with the tables structure and the
Dataloader cannot update the MIF information.

For example, you may see the following text in the Dataloader log:

CDefinedGroup::InsertDefinedAttribute - could not find table  $$<SMS_INVENTORY_DATA_LOADER>
SQL>>>rollback transaction  $$<SMS_INVENTORY_DATA_LOADER>
SQL>>>>> Done.  $$<SMS_INVENTORY_DATA_LOADER>
CGroup::DefineAttributes - couldn't defined attribute  $$<SMS_INVENTORY_DATA_LOADER>
CGroup::DefineGroupAndAttributes - couldn't define attributes for MICROSOFT|INVENTORY_FILES|1.0  $$<SMS_INVENTORY_DATA_LOADER>
CMachineSource::InsertMachine - could not validate machine  $$<SMS_INVENTORY_DATA_LOADER>
~Cannot process MIF XGY6OD1Q5.MIF, moving it to D:\SMS\inboxes\dataldr.box\BADMIFS\IUSH4YZ5.MIF  

In some instances, when the group class is re-created, duplicate stored
procedures may exist. Changes to the name of the MIF or the data collected by
the MIF will result in changes to the table name and table contents
respectively. To determine which stored procedure should be retained, examine
the properties of the stored procedure for reference to the tables being
queried.

Additional query words: prodsms

======================================================================
Keywords          : kbtool kbDatabase kbsms200 kbsms200bug kbDataLoader 
Technology        : kbSMSSearch kbSMS200
Version           : :2.0
Issue type        : kbprb

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.