Q245231: SNA Server and Mode Session Limit Errors
Article: Q245231
Product(s): Microsoft SNA Server
Version(s): WINDOWS:2.11 (all SP),3.0 (all SP),4.0,4.0 SP1,4.0 SP2,4.0 SP3
Operating System(s):
Keyword(s):
Last Modified: 13-JUN-2001
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft SNA Server, versions 2.11 SP1, 2.11 SP2, 3.0 SP1, 3.0 SP2, 3.0 SP3, 3.0 SP4, 4.0, 4.0 SP1, 4.0 SP2, 4.0 SP3
-------------------------------------------------------------------------------
SYMPTOMS
========
This article explains possible causes of session limit errors in the application
event log. When the session limit is exceeded, users cannot start any additional
LU6.2 sessions. The following error messages may be recorded when the session
limit has been exceeded:
- Event 26: APPC session activation failure: session limit error
- Event 18: APPC session activation failure: BIND negative response or UNBIND
request received
Sense data = 0805 0000
WORKAROUND
==========
These error messages occur most frequently when the SNA Server connection is to
an AS/400. In addition to the error messages in the event log, users cannot
start new 5250 sessions and may report a blank screen. If you are trying to
establish a session to the AS/400, check the following:
- Use the SNA Server Manager APPC Session Viewer utility to check the session
limit and number of sessions in use for the local LU-remote LU-mode triplet.
It may be necessary to increase the session limits in the mode definition.
Note: The maximum session limit for a mode on the AS/400 is 512. If you
require more than 512 sessions to an AS/400, create another local LU and
enable the Member of Default outgoing Local APPC LU Pool check box.
- 5250 sessions require a unique device name for each session. Verify that the
user is not attempting to use a device name that is already in use.
- Verify that the mode QPCSUPP has not been deleted from SNA Server or the
AS/400. This mode should exist on both the SNA Server and the AS/400.
- If there is a 5494 controller between the SNA Server and the AS/400, the 5494
may be limiting the number of sessions available. By default, the 5494
controller is limited to 32 sessions; however, a patch is available from IBM
to increase this limit to 128.
For additional information about increasing mode session limits, click the
article number below to view the article in the Microsoft Knowledge Base:
Q126395 Ways to Increase the Number of AS/400 LU6.2 Sessions
Additional query words:
======================================================================
Keywords :
Technology : kbAudDeveloper kbSNAServSearch kbSNAServ400 kbSNAServ211SP1 kbSNAServ211SP2 kbSNAServ300SP3 kbSNAServ300SP1 kbSNAServ400SP1 kbSNAServ400SP2 kbSNAServ400SP3 kbSNAServ300SP2 kbSNAServ300SP4
Version : WINDOWS:2.11 (all SP),3.0 (all SP),4.0,4.0 SP1,4.0 SP2,4.0 SP3
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.
Copyright Microsoft Corporation 1986-2002.