Q239707: TN3270 Clients May Fail to Reconnect to a Host Session
Article: Q239707
Product(s): Microsoft SNA Server
Version(s): WINDOWS:4.0 SP2
Operating System(s):
Keyword(s): kbsna400sp3fix kbsna400sp2
Last Modified: 01-OCT-1999
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft SNA Server, version 4.0 SP2
-------------------------------------------------------------------------------
SYMPTOMS
========
When TN3270 emulators are connecting through the TN3270 server (included with
SNA Server 4.0 Service Pack 2) to a host session, the TN3270 emulators may fail
to automatically reconnect if the session is terminated unexpectedly. The TN3270
emulator will reconnect to a host session if the user presses the Enter key.
The following message may be displayed in the TN3270 emulator window when the
host session is terminated unexpectedly:
TN3270E Service Error 505
SNA API verb <verb> failed.
NOTE: This message may not be displayed in the same manner for all TN3270
emulators.
When TN3270 emulators are configured to automatically connect, they successfully
reconnect to a host session after receiving the previous error message. This
occurs without any user intervention when they are connecting to a host session
through a TN3270 server, included with SNA Server versions prior to 4.0 Service
Pack 2 (SP2).
CAUSE
=====
The TN3270 server in SNA Server 4.0 SP2 was updated to use Windows NT I/O
Completion Ports to provide performance improvements. It is the use of I/O
Completion Ports that causes this particular problem to occur. Therefore, the
TN3270 server included with earlier versions of SNA Server does not exhibit this
behavior.
RESOLUTION
==========
To resolve this problem, obtain the latest service pack for SNA Server version
4.0. For additional information, please see the following article in the
Microsoft Knowledge Base:
Q215838 How to Obtain the Latest SNA Server Version 4.0 Service Pack
STATUS
======
Microsoft has confirmed this to be a problem in Microsoft SNA Server version 4.0
SP2. This problem was first corrected in SNA Server version 4.0 Service Pack 3.
MORE INFORMATION
================
For additional information about a similar TN3270 issue with SNA Server 4.0 SP2,
please click the article number(s) below to view the article(s) in the Microsoft
Knowledge Base:
Q230220 Emulators May Fail to Reconnect After Inactivity Timeout
Additional query words:
======================================================================
Keywords : kbsna400sp3fix kbsna400sp2
Technology : kbAudDeveloper kbSNAServSearch kbSNAServ400SP2
Version : WINDOWS:4.0 SP2
Issue type : kbbug
Solution Type : kbfix
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.