Q221790: IIS Runs Out of Work Items and Causes RPC Failures

Article: Q221790
Product(s): Windows for Workgroups and Windows NT Networking Issues
Version(s): 4.0,5.0
Operating System(s): 
Keyword(s): 
Last Modified: 31-JUL-2002

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Internet Information Server version 4.0 
- Microsoft Internet Information Services version 5.0 
-------------------------------------------------------------------------------

IMPORTANT: This article contains information about modifying the registry. Before you 
modify the registry, make sure to back it up and make sure that you understand how to restore 
the registry if a problem occurs. For information about how to back up, restore, and edit the 
registry, click the following article number to view the article in the Microsoft Knowledge Base:

  Q256986 Description of the Microsoft Windows Registry

SYMPTOMS
========

In a Web farm environment, where one or more IIS Web servers are using a remote
Windows NT or Windows 2000 file server to hold the content for the Web site (for
example, the home directory or the virtual directories for the Web site are
mapped to a UNC path), the IIS Web servers may run out of available work
contexts at the redirector level. When this happens, the following symptoms can
occur on your IIS Web servers:

- IIS appears to stop responding. If you examine a process dump of
  Inetinfo.exe, you will see that a large number of worker threads are waiting
  to retrieve content from the remote file share. In a Performance Monitor log,
  IIS appears largely idle during this time, as the majority of the threads are
  in a wait state, waiting to access the remote server.

- On the local desktop of one of the IIS Web servers, if you attempt to use the
  client redirector to access the remote file share through Network
  Neighborhood or My Network Places, or through Windows Explorer, it appears to
  stop responding indefinitely. If a UNC path is mapped to a local drive letter
  in Windows Explorer, and Windows Explorer is open, it appears to stop
  responding as well. This can give the appearance that the entire operating
  system has stopped responding, when in fact it has not.

- The following error messages may occur when the maximum number of work
  contexts are exhausted on a particular server:

  RPC 1792 - The remote procedure call failed and did not execute.

  Netlogon 5719 - Unable to find domain controller.

  These error messages may occur when you attempt to make any additional RPC
  connections to a server when the maximum number of work contexts is reached.


CAUSE
=====

The server is running out of work contexts for a particular client. In Windows
2000, there is a hard-coded upper limit of 125 work contexts for all types of
clients (Windows NT, Windows 95, and Windows 98).

RESOLUTION
==========

WARNING: If you use Registry Editor incorrectly, you may cause serious problems
that may require you to reinstall your operating system. Microsoft cannot
guarantee that you can solve problems that result from using Registry Editor
incorrectly. Use Registry Editor at your own risk.

1. If you are running Windows 2000, install the post-SP1 hotfix described in the
  following Microsoft Knowledge Base article to both the IIS servers and the
  file server:

  Q271148 MaxMpxCt and MaxCmds Limits in Windows 2000

2. Increase the values of MaxCmds on the IIS Servers and MaxMpxCT on the File
  Server by using the following registry scripts:

   - Save the following registry script as Client.reg, and then run it on the
     IIS servers:

  Windows Registry Editor Version 5.00

  [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\lanmanworkstation\parameters]
  "MaxCmds"=dword:00000800

   - Save the following registry script as Server.reg, and then run it on the
     file server:

  Windows Registry Editor Version 5.00

  [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\lanmanserver\parameters]
  "MaxMpxCT"=dword:00000800
  "MaxWorkItems"=0x00002000

  By default, these scripts specify a MaxCmds and MaxMpxCT of 2,048, which
  should be sufficient for most situations. MaxWorkItems has been specified at
  4x MaxMpxCt or 8,192. For more information on these settings, see the "More
  Information" section of this article.

3. Restart all of the IIS servers and the file server for these changes to take
  effect.

NOTE: Increasing these values consumes additional non-paged pool memory on the
file server and the IIS clients. Non-paged pool memory has an upper limit of 256
megabytes (MB). A large number of clients with a large number of connections can
consume all of the non-paged pool memory on the file server. Use Performance
Monitor to watch this counter and to make sure that it is not approaching the
limit.

STATUS
======

Microsoft has confirmed that this is a problem in the Microsoft products that
are listed at the beginning of this article.

MORE INFORMATION
================

After you apply the hotfix described in Q271148, the upper limit for MaxMpxCt
(the server setting) changes from 125 to 65,535, and on the client, the upper
limit for MaxCmds (the client setting) changes from 255 to 65,535.

Additionally, the maximum number of concurrent SMB sessions that can be opened
between the client and the server is the lower of MaxCmds and MaxMpxCT .
However, if the connecting client is a Windows 95 or Windows 98 client, then the
effective value of MaxMpxCt for that client is limited to 125.

These limits become important when you use IIS in a Web-farm scenario where the
content for the Web sites is stored on a remote UNC share, because IIS uses the
ReadDirectoryChangesW API to receive file change notifications. This is done so
that if files change, IIS can un-cache the old files, and then re-read the new
files from the disk or share. When you use a UNC path as the home directory, a
persistent SMB connection remains open between the IIS server and the file
server, which consumes a work context. If the directory structure is large
enough, it is possible to run out of work contexts and encounter the symptoms
listed previously.

A computer running IIS can have multiple virtual directories or Web sites
pointing to shares on another Windows NT Server computer. The ASP Directory
Monitor uses the ReadDirectoryChangesW API to monitor for any changes to those
directories on the other server. Each pending ReadDirectoryChangesW requires a
work context on the server, and there is only a limited number of work contexts
available.

The number of work contexts is passed from the server to the client when the SMB
level is negotiated. The redirector on the client keeps an internal count of the
number of work contexts that it is using on the server. The default number of
work contexts is 50.

The number of work contexts is limited to keep the server process from consuming
all non-paged pool memory. This can be raised, but then there is a limit to how
many work contexts a particular client can consume.

This problem is not limited to IIS. Windows NT Explorer uses the same mechanism
to monitor for directory changes.

For additional information about the MaxWorkItems and MaxMpxCT settings, click
the article numbers below to view the articles in the Microsoft Knowledge Base:

  Q232476 Terminal Server Connections and Logon Limited by MaxWorkItems

  Q271148 MaxMpxCt and MaxCmds Limits in Windows 2000

  Q216171 Server Performance Degrades During Work Item Allocation

Additional query words: rdr

======================================================================
Keywords          :  
Technology        : kbiisSearch kbiis500 kbiis400
Version           : :4.0,5.0
Issue type        : kbbug
Solution Type     : kbpending

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.