KnowledgeBase Archive

An Archive of Early Microsoft KnowledgeBase Articles

View on GitHub

Q221634: FIX: C0000005 Error With CLOSE ALL in Project Hook BeforeBuild

Article: Q221634
Product(s): Microsoft FoxPro
Version(s): WINDOWS:6.0
Operating System(s): 
Keyword(s): kbservicepack kbvfp600 kbvfp600bug kbVS600sp2 kbVS600SP1 kbVS600sp3fix kbGrpDSFox
Last Modified: 21-MAY-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Visual FoxPro for Windows, version 6.0 
-------------------------------------------------------------------------------

SYMPTOMS
========

Issuing a CLOSE ALL command in the BeforeBuild event of the Project Hook object
causes the following error:

  Mismatched pushjmp/popjmp call

After the error appears, clicking OK in the dialog box causes Visual FoxPro 6.0
to terminate with a C0000005 error or an application error message under Windows
NT.

STATUS
======

Microsoft has confirmed this to be a bug in the Microsoft products listed at the
beginning of this article.

This bug was corrected in Visual Studio 6.0 Service Pack 3. For more information
about Visual Studio service packs, please see the following articles in the
Microsoft Knowledge Base:

Q194022 INFO: Visual Studio 6.0 Service Packs, What, Where, Why

Q194295 HOWTO: Tell That Visual Studio 6.0 Service Packs Are Installed

MORE INFORMATION
================

Steps to Reproduce Behavior
---------------------------

1. Create a PRG.

2. Cut and paste the code below into the PRG:

  oProject=CREATEOBJECT("myprojecthook")

  STRTOFILE("wait window","main.prg")
  MODIFY PROJECT test NOWAIT

  _VFP.ActiveProject.Files.Add("main.prg")
  _VFP.ActiveProject.ProjectHook=oProject
  _VFP.ActiveProject.Build

  DEFINE CLASS myprojecthook As projecthook

     PROCEDURE BeforeBuild
     LPARAMETERS cOutputName, nBuildAction, lRebuildAll, lShowErrors, lBuildNewGuids
        CLOSE ALL
     ENDPROC

  ENDDEFINE
   

3. Save and run the PRG.

  Note that Visual FoxPro produces a dialog box containing the "Mismatched
  pushjmp/popjmp call" error. When you click OK, Visual FoxPro terminates with
  C0000005 error or an application error message under Windows NT.

Additional query words:

======================================================================
Keywords          : kbservicepack kbvfp600 kbvfp600bug kbVS600sp2 kbVS600SP1 kbVS600sp3fix kbGrpDSFox 
Technology        : kbVFPsearch kbAudDeveloper kbVFP600
Version           : WINDOWS:6.0
Issue type        : kbbug
Solution Type     : kbfix

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.