Q214756: "Path Not Found" When Connecting to a Novell NetWare Server
Article: Q214756
Product(s): Microsoft Windows NT
Version(s): winnt:4.0
Operating System(s):
Keyword(s): kberrmsg kbnetwork 3rdpartynet kb3rdPartyNetClient
Last Modified: 27-JUL-2001
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Windows NT Workstation version 4.0
- Microsoft Windows NT Server version 4.0
- Microsoft Windows NT Server, Enterprise Edition version 4.0
-------------------------------------------------------------------------------
SYMPTOMS
========
When you attempt to connect to a Novell NetWare server with a computer running
Microsoft Windows NT 4.0 using Gateway (and Client) Services for NetWare (GSNW),
you may receive the following error message:
Error 53 - The network path is not found
RESOLUTION
==========
To resolve this issue:
1. Verify that the GSNW software is properly installed. Click Start, point to
Settings, click Control Panel, and then double-click Network.
2. Click the Services tab, click Gateway Service for NetWare, click Remove, and
then click Yes.
3. Click the Protocols tab, click NWLink IPX/SPX Compatible Transport, click
Remove, click Yes, click Close, and then restart the computer when you are
prompted.
4. After the computer restarts and you log on, click Start, point to Settings,
click Control Panel, and then double-click Network.
5. Click the Protocols tab, click Add, and then double-click NWLink IPX/SPX
Compatible Transport. When you are prompted, type the full path to the
installation files folder (for example, D:\I386), and then click Continue.
6. When you are prompted to restart the computer, click Do Not Restart Windows.
7. Reapply the latest Windows NT 4.0 service pack. For information about
obtaining and installing the latest service pack for Windows NT 4.0, see the
following article in the Microsoft Knowledge Base:
Q152734How to Obtain the Latest Windows NT 4.0 Service Pack
8. Restart the computer when the service pack installation is complete.
9. Verify that you have properly configured a preferred NetWare server when you
log on. Click Start, point to Settings, click Control Panel, and then
double-click GSNW.
10. In the list of available NetWare servers, click the appropriate server name,
and then click OK.
11. Verify that the NWLINK IPX/SPX protocol is configured correctly. For
information on how to do this, please refer to the following article in the
Microsoft Knowledge Base:
Q166963Cannot Communicate with Computer Running NWLink IPX/SPX
NOTE: You can obtain the correct values for your network installation by
typing "config" (without the quotation marks) at a NetWare server console
command line.
Additional query words:
======================================================================
Keywords : kberrmsg kbnetwork 3rdpartynet kb3rdPartyNetClient
Technology : kbWinNTsearch kbWinNTWsearch kbWinNTW400 kbWinNTW400search kbWinNT400xsearch kbWinNTSsearch kbWinNTSEntSearch kbWinNTSEnt400 kbWinNTS400xsearch kbWinNTS400
Version : winnt:4.0
Hardware : ALPHA x86
Issue type : kbprb
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.
Copyright Microsoft Corporation 1986-2002.