KnowledgeBase Archive

An Archive of Early Microsoft KnowledgeBase Articles

View on GitHub

Q190530: FIX: ActiveX Control Events Are Not Fired in ATL Dialog

Article: Q190530
Product(s): Microsoft C Compiler
Version(s): 3.0,6.0
Operating System(s): 
Keyword(s): kbnokeyword kbActiveX kbCOMt kbConnPts kbCtrl kbDlg kbVC600bug kbATL300bug kbGrpDSMFCAT
Last Modified: 11-FEB-2002

-------------------------------------------------------------------------------
The information in this article applies to:

- The Microsoft Active Template Library (ATL) 3.0, used with:
   - Microsoft Visual C++, 32-bit Enterprise Edition, version 6.0 
   - Microsoft Visual C++, 32-bit Professional Edition, version 6.0 
   - Microsoft Visual C++, 32-bit Learning Edition, version 6.0 
-------------------------------------------------------------------------------

SYMPTOMS
========

When you insert an ActiveX control on an ATL dialog box, and add event handlers
for it, the event handler is not called.

CAUSE
=====

This problem occurs because the sink objects have not been hooked up to the
corresponding ActiveX control [IConnectionPoint::Advise() has not been called
for each control].

RESOLUTION
==========

For an ATL dialog box, IConnectionPoint::Advise() can be called for each control
on the dialog box, with associated event handlers, by calling
AtlAdviseSinkMap(). Add a message handler for WM_INITDIALOG in the dialog box
and call AtlAdviseSinkMap(). For example:

     LRESULT OnInitDialog(UINT uMsg, WPARAM wParam, LPARAM lParam,
        BOOL& bHandled)
     {
        // Calls IConnectionPoint::Advise() for each control on the dialog
        // box with sink map entry.
        AtlAdviseSinkMap(this, TRUE);

        return 1;  // Let the system set the focus.
     }

Also, make sure IConnectionPoint::Unadvise() is called for all controls for which
IConnectionPoint::Advise() was called. This is done by calling
AtlAdviseSinkMap() with the value FALSE for last parameter:

     LRESULT OnDestroy(UINT uMsg, WPARAM wParam, LPARAM lParam,
        BOOL& bHandled)
     {
        // Calls IConnectionPoint::Unadvise() for each control on the dialog
        // box with sink map entry.
        AtlAdviseSinkMap(this, FALSE);

        return 0;
     }

STATUS
======

Microsoft has confirmed this to be a bug in the Microsoft products listed at the
beginning of this article.

This problem was corrected in Microsoft Visual C++ .NET.

MORE INFORMATION
================

Steps to Reproduce Behavior
---------------------------

1. Create a default ATL AppWizard EXE.

2. Using the ATL Object Wizard (on the Insert menu, click New ATL Object),
  insert a dialog box from the miscellaneous category.

3. In the dialog box resource inserted by the above step, right-click and select
  "Insert ActiveX Control"; insert an ActiveX control that has an event
  interface.

4. Right click the inserted ActiveX control and select Events. In the resulting
  message/event handler dialog box, add event handlers for the ActiveX control.

5. Create an instance of the dialog box, and display it through a call to
  DoModal() or Create().

6. Build and run the application and cause the ActiveX control to fire the event
  for which the handler was added in the previous step. Note that the event
  handler is not called.

(c) Microsoft Corporation 1998, All Rights Reserved. Contributions by Jaganathan
Thangavelu, Microsoft Corporation
(c) Microsoft Corporation 1998, All Rights Reserved.
Contributions by Jaganathan Thangavelu, Microsoft Corporation


Additional query words: kbATL300 kbATL300bug kbATL kbVC600 kbVC600bug

======================================================================
Keywords          : kbnokeyword kbActiveX kbCOMt kbConnPts kbCtrl kbDlg kbVC600bug kbATL300bug kbGrpDSMFCATL kbNoUpdate 
Technology        : kbVCsearch kbAudDeveloper kbATLsearch
Version           : :3.0,6.0
Issue type        : kbbug
Solution Type     : kbfix

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.