KnowledgeBase Archive

An Archive of Early Microsoft KnowledgeBase Articles

View on GitHub

Q189324: SNA Server Manager Shows Incorrect DLC t1 Timer Value

Article: Q189324
Product(s): Microsoft SNA Server
Version(s): WINDOWS:3.0 SP3,4.0,4.0 SP1
Operating System(s): 
Keyword(s): kbbuglist
Last Modified: 24-SEP-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft SNA Server, versions 3.0 SP3, 4.0, 4.0 SP1 
-------------------------------------------------------------------------------

SYMPTOMS
========

In SNA Server Manager, the 802.2 DLC tab of the DLC Connection Properties dialog
box reports incorrect values for T1 timer ticks.

The drop-down list box reports the following:

  Ticks    T1       T2      Ti
  ------------------------------
     1    200 ms    40 ms    1 s
     2    400 ms    80 ms    2 s
     3    600 ms    120 ms   3 s
     4    800 ms    160 ms   4 s
     5      1 s     200 ms   5 s
     6      1 s     400 ms   5 s
     7      2 s     800 ms  10 s
     8      3 s    1200 ms  15 s
     9      4 s    1600 ms  20 s
    10   2000 ms   2000 ms  25 s

The drop-down list box should report the following:

  Ticks    T1       T2      Ti
  ------------------------------
    1    200 ms     40 ms    1 s
    2    400 ms     80 ms    2 s
    3    600 ms    120 ms    3 s
    4    800 ms    160 ms    4 s
    5      1 s     200 ms    5 s
    6      1 s     400 ms    5 s
    7      2 s     800 ms   10 s
    8      3 s    1200 ms   15 s
    9      4 s    1600 ms   20 s
   10      5 s    2000 ms   25 s

(T1 timer 10 should be "5 s" instead of "2000 ms").

CAUSE
=====

This error happens because of a mismatch on the table where timer tick values
are associated with a text string indicating the corresponding amount of time.

RESOLUTION
==========

Microsoft has confirmed this to be a problem in SNA Server versions 3.0 SP3,
4.0, and 4.0 SP1. We are researching this problem in SNA Server version 3.0 and
will post more information here in the Knowledge Base as it becomes available.

This problem was corrected in the latest SNA Server version 4.0 U.S. Service
Pack. For information on obtaining this Service Pack, query on the following
word in the Microsoft Knowledge Base (without the spaces):

  S E R V P A C K

NOTE: A similar problem existed in SNA Server 3.0 and 3.0 SP1. It was corrected
in SNA Server 3.0 SP2.

WORKAROUND
==========

To work around this problem:

- Use the Snacfg.exe command line tool

MORE INFORMATION
================

With the fix applied, the table is updated so the text strings now indicate the
real amount of time for each of the 10 T1, T2, and Ti timer Ticks, as shown on
the second table above.

For additional information, please see the following articles in the Microsoft
Knowledge Base:

  Q172434 Manager Displays Wrong Values for 802.2 T1 and Ti Timer Ticks

Additional query words:

======================================================================
Keywords          :  kbbuglist
Technology        : kbAudDeveloper kbSNAServSearch kbSNAServ400 kbSNAServ300SP3 kbSNAServ400SP1
Version           : WINDOWS:3.0 SP3,4.0,4.0 SP1
Issue type        : kbbug
Solution Type     : kbfix

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.