Q188819: XFOR: OV/VM Connector Returns Different NDRs to PROFS Sender
Article: Q188819
Product(s): Microsoft Exchange
Version(s): winnt:5.0,5.5
Operating System(s):
Keyword(s):
Last Modified: 17-DEC-1999
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Exchange Server, versions 5.0, 5.5
-------------------------------------------------------------------------------
SYMPTOMS
========
Messages sent from PROFS to unknown PROFS addresses in Exchange using the
LinkAge version 3.2 Connector or the Microsoft Exchange Connector for IBM OV/VM
version 5.5 may result in different types of non-delivery reports (NDRs) being
returned.
+-----------------+
| PROFS |
| |
| NODE3(USER3) |
+--------+--------+
|
| OV/VM Connector
|
+--------+--------+ +-----------------+
| Exchange Site 1 | X.400 Connector| Exchange Site 2 |
| +----------------+ |
| NODE1(USER1) | with Dir Rep | NODE2(USER2) |
+-----------------+ +-----------------+
Address Space on OV/VM Connector in Site 1:
PROFS * cost=1
Address Space on X.400 Connector in Site 1:
PROFS NODE2(*) cost=1
NOTE: This particular Address Space is not required to reproduce the NDR
behavior.
Address Space on X.400 Connector in Site 2:
PROFS * cost=1
1. Messages sent from a PROFS user to an unknown PROFS address in Site 1 result
in an NDR similar to the following:
BADUSER unknown at NODE1; <date and time> not received.
The conditions leading to the production of this NDR are explained in the
CAUSE section (1), below.
2. Messages sent from a PROFS user to an unknown PROFS address in Site 2 result
in a different NDR message:
NODE2 cannot deliver <date and time> to BADUSER.
This NDR does not indicate that the PROFS address was unknown. The conditions
leading to the production of this NDR are explained in the CAUSE section (2),
below.
CAUSE
=====
This behavior is by design. The reason for the differences in the NDR messages
is that the delivery error is detected at different points in the mail network.
Depending upon the location in the network, where the problem is detected, and
the circumstances under which it is detected, the NDR is created. It is not
possible or desirable to guarantee the same error message for different "bad
recipients."
A fundamental function of the connectors (PROFS, SNADS, and Notes) is to allow
the use of Exchange as a messaging backbone. As part of this feature, it is not
required that every address in every attached messaging system be registered in
the Exchange directory adjacent to the connector. In fact, Exchange
administrators may decide, for various reasons, not to enable directory
synchronization (dirsync) between Exchange and PROFS. However, even if dirsync
is enabled, directory replication latency may cause a valid address not to be
immediately present in a directory.
1. When a PROFS user sends an address to NODE1 (BADUSER) in the topology shown
above, the connector determines that NODE1 is the PROFS proxy node name by
reading the site addressing. The connector categorically knows that all proxy
addresses with the node name of NODE1 must be registered in Site 1's Exchange
directory. When the address lookup fails, the connector knows the user does
not exist and immediately generates the appropriate error code for an unknown
address NDR.
When a PROFS user sends an address to NODE2(BADUSER), the connector knows that
NODE2 is not the PROFS proxy node name for the immediate site. Because
NODE2(BADUSER) cannot be found in Site 1's directory, the message is
submitted to the Exchange backbone for routing.
2. If there is a specific NODE2(*) PROFS Address Space defined on the X.400
Connector leading to Site 2, the message transfer agent (MTA) routes the
message to the other Site, where the receiving MTA attempts to resolve the
address. If the address does not exist in Site 2's directory, the MTA once
again routes the message, based on Site 2's GWART. Site 2 has a PROFS *
Address Space defined on the X.400 Connector, which causes the MTA to route
the message back to Site 1. The MTA in Site 1 eventually routes the message
back to the OV/VM Connector based on the PROFS * Address Space defined on the
OV/VM Connector. The OV/VM Connector detects that the message is looping and
generates the error code that causes the following NDR to be generated:
NODE2 cannot deliver <date and time> to BADUSER.
The looping message condition is detected even more quickly when the PROFS *
Address Space defined on the OV/VM Connector is the only PROFS Address Space
defined in Site 1.
Additional query words:
======================================================================
Keywords :
Technology : kbExchangeSearch kbExchange500 kbExchange550 kbZNotKeyword2
Version : winnt:5.0,5.5
Issue type : kbprb
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.