KnowledgeBase Archive

An Archive of Early Microsoft KnowledgeBase Articles

View on GitHub

Q184998: RDR May Read or Write from Wrong File If File Is Memory Mapped

Article: Q184998
Product(s): Microsoft Windows NT
Version(s): WinNT:4.0
Operating System(s): 
Keyword(s): kbWinNT400sp4fix
Last Modified: 09-AUG-2001

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Windows NT Workstation version 4.0 
- Microsoft Windows NT Server version 4.0 
- Microsoft Windows NT Server version 4.0, Terminal Server Edition 
-------------------------------------------------------------------------------


SYMPTOMS
========

An application may write data to or read data from the wrong file if a client
has the file open and an error occurs causing the network connection to close.

NOTE: This problem can occur only if the file is a memory-mapped file.

CAUSE
=====

When the connection is closed, the RDR does not check the status of a
memory-mapped file.

RESOLUTION
==========

To resolve this problem, obtain the latest service pack for Windows NT 4.0 or
Windows NT Server 4.0, Terminal Server Edition. For additional information,
please see the following article in the Microsoft Knowledge Base:

  Q152734 How to Obtain the Latest Windows NT 4.0 Service Pack


STATUS
======

Microsoft has confirmed this to be a problem in Windows NT 4.0 and Windows NT
Server 4.0, Terminal Server Edition. This problem was first corrected in Windows
NT 4.0 Service Pack 4.0 and Windows NT Server 4.0, Terminal Server Edition
Service Pack 4.


MORE INFORMATION
================

The Windows NT Rdr.sys logs on to the server using your user name/password and
receives a UID number to reference the session in future requests. The same is
true for files. When a file is opened, the server will return a FID to reference
the file in future requests. The UID/FID pair is used to establish logon
privileges and file permissions in RDR requests. These UIDs and FIDs get
recycled each connection. On a new connection, the numbers assigned start at the
beginning. The issue is that, when the connection is closed, the RDR is notified
and will set a status in the file object so no further I/O can be done on the
file. However, the status is not checked in the case of a memory-mapped file.
This causes the RDR to use an old UID/FID pair. If the UID/FID pair were in use,
the wrong file would be accessed.
======================================================================
Keywords          : kbWinNT400sp4fix 
Technology        : kbWinNTsearch kbWinNTWsearch kbWinNTW400 kbWinNTW400search kbWinNT400search kbWinNTSsearch kbWinNTS400search kbWinNTS400 kbNTTermServ400 kbNTTermServSearch
Version           : WinNT:4.0
Issue type        : kbbug
Solution Type     : kbfix

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.