Q180709: Code in Main Thread Still Executes After Issuing CTRL+C Command

Article: Q180709
Product(s): Microsoft Windows NT
Version(s): WinNT:4.0
Operating System(s): 
Keyword(s): 
Last Modified: 10-AUG-2001

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Windows NT Workstation versions 3.51, 4.0 
- Microsoft Windows NT Server versions 3.51, 4.0 
-------------------------------------------------------------------------------

SYMPTOMS
========

After you press CTRL+C, a significant amount of code may still be executed in
the primary thread before the program quits.

CAUSE
=====

If there is a read outstanding to a console device and CTRL+C is pressed, the
Input/Output is cancelled and the read is completed. The thread that issued the
read then continues to run. Sometime later, the CTRL+C event is delivered (in a
different thread) to the Control Event handler which usually causes the process
to exit. The problem is that various amounts of code can execute in the primary
thread before the process ever exits. The amount of code that is executed
depends on the platform speed and processor.

STATUS
======

Microsoft has confirmed this to be a problem in Windows NT version 4.0. We are
researching this problem and will post new information here in the Microsoft
Knowledge Base as it becomes available.


Additional query words: prodnt
======================================================================
Keywords          :  
Technology        : kbWinNTsearch kbWinNTWsearch kbWinNTW400 kbWinNTW400search kbWinNT351search kbWinNT400search kbWinNTW351search kbWinNTW351 kbWinNTSsearch kbWinNTS400search kbWinNTS400 kbWinNTS351 kbWinNTS351search
Version           : WinNT:4.0
Hardware          : ALPHA x86
Issue type        : kbbug
Solution Type     : kbfix

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.