Q180416: APPC or CPI-C TPs May Fail When Using Dependent LU 6.2 Sessions

Article: Q180416
Product(s): Microsoft SNA Server
Version(s): WINDOWS:3.0,3.0 U.S. SP1,3.0 U.S. SP2,4.0
Operating System(s): 
Keyword(s): kbnetwork
Last Modified: 14-MAR-2000

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft SNA Server, versions 3.0, 3.0 U.S. SP1, 3.0 U.S. SP2, 4.0 
-------------------------------------------------------------------------------

SYMPTOMS
========

An APPC or CPI-C application may fail to get an active conversation with a host
if a previous conversation over the same Local APPC LU has ended. For example,
if there was a conversation over local LU LOCAL1 and remote LU REMOTE1, an APPC
or CPI-C application may fail to get an active conversation over local LU LOCAL1
and remote LU REMOTE2 even if the previous conversation has ended.

When this occurs, the APPC or CPI-C application call to [MC_]ALLOCATE or CMALLC
never completes because SNA Server has not unbound the previous dependent LU/LU
session before attempting to solicit a bind to a different Remote APPC LU.

NOTE: This does not occur when you use Independent LU 6.2 sessions.

For additional information about a related problem in SNA Server versions 3.0
SP3, 4.0 SP1, and 4.0 SP2, please see the following article in the Microsoft
Knowledge Base:

  Q225207 APPC/CPIC App Unable To Allocate Conversation over Dependent LU

CAUSE
=====

SNA Server is not ending the previous dependent APPC session by sending an
UNBIND to the host. This causes any additional APPC sessions over the same local
APPC LU and different remote APPC LUs to fail to get active conversations until
the first APPC session is shut down.

STATUS
======

Microsoft has confirmed this to be a problem in SNA Server versions 3.0, 3.0
SP1, 3.0 SP2, and 4.0.

This problem was corrected in the latest SNA Server versions 3.0 and 4.0 U.S.
Service Packs. For information on obtaining Service Packs, query on the
following word in the Microsoft Knowledge Base (without the spaces):

  S E R V P A C K


MORE INFORMATION
================

The SNA Server service has been updated so that it will send an UNBIND Cleanup
to the host to end the initial dependent APPC session if it is not active when
it receives a request to open a new APPC session over the same local APPC LU and
a different remote APPC LU.

Additional query words:

======================================================================
Keywords          : kbnetwork 
Technology        : kbAudDeveloper kbSNAServSearch kbSNAServ300 kbSNAServ400
Version           : WINDOWS:3.0,3.0 U.S. SP1,3.0 U.S. SP2,4.0
Hardware          : ALPHA x86
Issue type        : kbbug
Solution Type     : kbfix

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.