- Microsoft Visual FoxPro for Windows, versions 3.0, 3.0b, 5.0, 5.0a, 6.0
- Microsoft Visual FoxPro for Macintosh, version 3.0b
-------------------------------------------------------------------------------
SYMPTOMS
========
A form, on which a grid has focus, remains visible after the form has been
programmatically released and a modal form has been instantiated. The form
containing the grid remains visible until the modal form has been released.
RESOLUTION
==========
Set the visible property of the form containing the grid to False (.f.) before
releasing the form, using the following code:
PROCEDURE closescreens
IF _SCREEN.FORMCOUNT > 0
FOR i = _SCREEN.FormCount TO 1 STEP -1
_SCREEN.FORMS(i).VISIBLE=.F.
_SCREEN.FORMS(i).RELEASE
ENDFOR
ENDIF
RETURN
STATUS
======
Microsoft is researching this problem and will post new information here in the
Microsoft Knowledge Base as it becomes available.
MORE INFORMATION
================
This behavior is not observed when a form, containing a grid object, is
programmatically released under the following conditions:
- A grid object does not have focus.
- The WindowType property of the form being instantiated, after release of the
form containing the grid, is set to 0 - Modeless.
Steps to Reproduce Behavior
---------------------------
1. Create a form called gridfrm and place a grid object on the form.
2. Create a second form called modalfrm and set its WindowType property to 1 -
Modal.
3. Add the following code to the forms Click event:
=endjob()
4. Create a program file named Norelease.prg using the following code:
CLEAR
SET SYSMENU TO
SET SYSMENU AUTOMATIC
DEFINE PAD modal_frm OF _MSYSMENU PROMPT "\<Modal Form" COLOR
SCHEME 3 ;
KEY ALT+M, ""
DEFINE PAD exit_prg OF _MSYSMENU PROMPT "E\<xit" COLOR SCHEME 3 ;
KEY ALT+X, ""
ON SELECTION PAD modal_frm OF _MSYSMENU =runmodal()
ON SELECTION PAD exit_prg OF _MSYSMENU =endjob()
USE home()+"SAMPLES\DATA\CUSTOMER"
DO FORM gridfrm
READ EVENTS
SET SYSMENU TO DEFAULT
RETURN
PROCEDURE closescreens
IF _SCREEN.FORMCOUNT > 0
FOR i = _SCREEN.FORMCOUNT TO 1 STEP -1
_SCREEN.FORMS(i).RELEASE
ENDFOR
ENDIF
RETURN
PROCEDURE runmodal
=closescreens()
DO FORM modalfrm
RETURN
PROCEDURE endjob
=closescreens()
CLEAR EVENTS
RETURN
5. Run Norelease.prg.
6. Click the Modal Form menu item.
Additional query words:
======================================================================
Keywords : kbcode kbHWMAC kbvfp kbvfp300BUG kbvfp500bug kbvfp600bug
Technology : kbHWMAC kbOSMAC kbVFPsearch kbAudDeveloper kbVFP300bMac kbVFP300 kbVFP300b kbVFP500 kbVFP600 kbVFP500a
Version : MACINTOSH:3.0b;WINDOWS:3.0,3.0b,5.0,5.0a,6.0
Issue type : kbbug
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.
Copyright Microsoft Corporation 1986-2002.