Q177887: XCON: MTA Terminates Suddenly with 2175, 100, and 9405 Events
Article: Q177887
Product(s): Microsoft Exchange
Version(s): winnt:4.0,5.0
Operating System(s):
Keyword(s): kbusage
Last Modified: 19-MAR-2000
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Exchange Server, versions 4.0, 5.0
-------------------------------------------------------------------------------
SYMPTOMS
========
The Microsoft Exchange Message Transfer Agent (MTA) versions 4.0 and 5.0 may
terminate unexpectedly at startup with events similar to the following in the
Windows NT Event Viewer Application log:
9405
An unexpected error has occurred which may cause the MTA to terminate.
Error: Exception 0xc0000094 occurred at Address 0x4aac9b. [BASE DISP:
ROUTER 10] (16)
100
A fatal MTA database server error was encountered. The MTA work queue
could not be created. Internal database error: 2109. [MTA DISP:ROUTER
10 118] (16)
2175
An MTA database server error was encountered while an attribute length.
Called from MTA. Procedure: 118. Database error code: ODXOINIU - Object
does not exist. Object at fault: 0600007B. Attribute identifier: 2.
Value number: 1. Referenced object: 00000000 (00000000 => N/A).
Referenced object error 0. [DB Server DISP:ROUTER 10 72] (14)
STATUS
======
Microsoft has confirmed this to be a problem in Microsoft Exchange Server
versions 4.0, and 5.0.
A supported fix is now available, but has not been fully regression-tested and
should be applied only to systems experiencing this specific problem. Unless you
are severely impacted by this specific problem, Microsoft recommends that you
wait for the next Service Pack that contains this fix. Contact Microsoft Product
Support Services for more information.
RESOLUTION
==========
Customers who experience this problem on version 4.0 Exchange servers will need
to upgrade to Exchange 5.5. Customers experiencing this problem on Exchange 5.0,
will need to upgrade to Service Pack 2.
MORE INFORMATION
================
Exception 0xc0000094 is generated when a division by zero error has been
encountered. The MTA terminates unexpectedly when the MTA attempts to perform
integer division using the value of an attribute that has been erroneously set
to a value of zero.
Additional query words:
======================================================================
Keywords : kbusage
Technology : kbExchangeSearch kbExchange500 kbExchange400 kbZNotKeyword2
Version : winnt:4.0,5.0
Issue type : kbbug
Solution Type : kbfix
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.
Copyright Microsoft Corporation 1986-2002.