Q176258: BUG: Refresh Method of Data Control Resets QueryTimeout

Article: Q176258
Product(s): Microsoft Visual Basic for Windows
Version(s): WINDOWS:5.0
Operating System(s): 
Keyword(s): kbVBp500 kbGrpDSVBDB
Last Modified: 11-JAN-2001

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Visual Basic Control Creation Edition for Windows, version 5.0 
- Microsoft Visual Basic Learning Edition for Windows, version 5.0 
- Microsoft Visual Basic Professional Edition for Windows, version 5.0 
- Microsoft Visual Basic Enterprise Edition for Windows, version 5.0 
-------------------------------------------------------------------------------

SYMPTOMS
========

The QueryTimeout property of the Database object determines the number of
seconds to wait before a timeout occurs when a query is executed. If the
DefaultType property of the Data control is set to dbUseODBC, then the
QueryTimeout property of the Database object is reset to the default value of 30
when the Refresh method of the Data control is performed.

RESOLUTION
==========

There are several ways to work around this problem, two of which are listed
here:

- Modify the DefaultType property of the Data control to dbUseJet.

- Use the Remote Data Control (MSRDC) rather than the Data control.

However, if it is necessary to use the Data control with an ODBC data source, the
following workaround can be used:

     Private ws As Workspace
     Private db As Database

     Private Sub Command1_Click()
     Dim con As String
     Dim sql As String

         con = "ODBC;DSN=your_dsn;UID=sa;PWD=;DATABASE=pubs"
         Set ws = DBEngine.CreateWorkspace("", "", "", dbUseODBC)
         Set db = ws.OpenDatabase("", Connect:=con)

         db.QueryTimeout = 60

         sql = "SELECT * FROM Authors"
         Set Data1.Recordset = db.OpenRecordset(sql, dbOpenDynaset)

         MsgBox db.QueryTimeout
     End Sub

STATUS
======

Microsoft has confirmed this to be a bug in the Microsoft products listed at the
beginning of this article. We are researching this bug and will post new
information here in the Microsoft Knowledge Base as it becomes available.

MORE INFORMATION
================

Steps to Reproduce Behavior
---------------------------

1. Start Visual Basic and create a new Standard EXE. Form1 is created by
  default.

2. Add a Data control and a CommandButton to Form1.

3. Add the following code to the General Declarations section of Form1:

        Private Sub Command1_Click()

            Data1.Database.QueryTimeout = 60

            Data1.RecordSource = "SELECT * FROM Authors"
            Data1.Refresh

            MsgBox Data1.Database.QueryTimeout

        End Sub

        Private Sub Form_Load()

            Data1.DefaultType = dbUseODBC
            Data1.Connect = "ODBC;DSN=your_dsn;UID=sa;PWD=;DATABASE=pubs"
            Data1.Refresh

        End Sub

4. Run the project.

5. Click on Command1 and note that the QueryTimeout is the default value of 30,
  rather than 60 that it was assigned to.

======================================================================
Keywords          : kbVBp500 kbGrpDSVBDB 
Technology        : kbVBSearch kbAudDeveloper kbZNotKeyword6 kbZNotKeyword2 kbVB500Search kbVBA500Search kbVBA500 kbVB500 kbZNotKeyword3
Version           : WINDOWS:5.0
Issue type        : kbbug

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.