Q174694: XFOR: OV/VM Connector "Waiting for NJE Signon" After BIND

Article: Q174694
Product(s): Microsoft Exchange
Version(s): winnt:4.0
Operating System(s): 
Keyword(s): exc4
Last Modified: 26-JUN-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Exchange Server, version 4.0 
-------------------------------------------------------------------------------

SYMPTOMS
========

During initial set up of the LinkAge Exchange-OV/VM Connector (also referred to
as the Exchange PROFS Connector), the connector appears to BIND properly to the
Remote Spooling Communications Subsystem (RSCS) application, but no mail is
exchanged. The last line in the LinkAge Exchange-OV/VM Connector logs for the
LME-PROFS-NJE process is:

  1997/10/01 12:02:07- LME-PROFS-NJE(01b7) 2 23353:SNA connection to the
     host has been established
  << NJESNA(3402)
  1997/10/01 12:02:07- LME-PROFS-NJE(01b7) 4 23224:NJE Connection opened
  << njeconn(459)
  1997/10/01 12:02:07- LME-PROFS-NJE(01b7) 4 23230:Waiting for initial
     contact (FMH-4) from NJE partner application
  << njeconn(883)
  1997/10/01 12:02:08- LME-PROFS-NJE(01b7) 4 23204:FMH4: optimized fanout
     supported
  << njeconn(831)
  1997/10/01 12:02:08- LME-PROFS-NJE(01b7) 4 23205:FMH4: signon supported
  << njeconn(837)
  1997/10/01 12:02:08- LME-PROFS-NJE(01b7) 3 23229:Waiting for NJE Signon
     from host
  << njeconn(1119)

After five minutes the following errors are logged:

  1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 23356:Timeout occurred when
     waiting for an LUA verb to complete
  << NJESNA(631)
  1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 23349:Error {Session timeout
     occurred} occurred when reading SNA data from the host
  << NJESNA(3599)
  1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 23217:Error occurred when
     waiting for the signon record from the host
  << njeconn(1126)
  1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 00510:Error {Session timeout
     occurred}: The application failed to initialize.
  << stdmain(858)

CAUSE
=====

The connector and RSCS are supposed to exchange a node signon, and the
initiating partner is the one with the alphabetically higher node name. The logs
above indicate that neither side is initiating the node signon because the
LinkAge Exchange-OV/VM Connector is not configured properly. The LOCALNODE=
parameter in the Linkage.ini file located in C:\Linkage has to match the LINKID
parameter in the RSCS LINK or the LINKDEF statement in the RSCS configuration
file, and the PARTNERNODE= parameter has to match the RSCS node ID.

If the RSCS node ID is alphabetically lower than the LINKID name for the
connector, then RSCS does not initiate the node signon. And if the LinkAge
Exchange-OV/VM Connector is configured so that its LOCALNODE= parameter is
alphabetically lower than the PARTNERNODE= parameter, the connector will not
initiate either, and you will see the above logged errors as a result.

RESOLUTION
==========

Correct the LOCALNODE= and PARTNERNODE= parameters to match the values specified
in the RSCS configuration file. The LOCALNODE= parameter should match the LINKID
parameter in the RSCS LINK or LINKDEF statement, and the PARTNERNODE= parameter
should match the LOCALID parameter (both definitions are located in the RSCS
configuration file).

Additional query words: SEND RECEIVE

======================================================================
Keywords          : exc4 
Technology        : kbExchangeSearch kbExchange400 kbZNotKeyword2
Version           : winnt:4.0
Issue type        : kbprb

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.