Q171624: Win16 SNA App May Hang Over SNA Win 3.x TCP/IP Sockets Interface
Article: Q171624
Product(s): Microsoft SNA Server
Version(s): WINDOWS:2.0,2.1,2.11 SP1;2.11 SP2,3.0 (all SP),4.0,4.0 SP1,4.0 SP2,4.0 SP3
Operating System(s):
Keyword(s):
Last Modified: 12-JUN-2001
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft SNA Server, versions 2.0, 2.1, 2.11 SP1, 2.11 SP2, 3.0 SP1, 3.0 SP2, 3.0 SP3, 3.0 SP4, 4.0, 4.0 SP1, 4.0 SP2, 4.0 SP3
-------------------------------------------------------------------------------
SUMMARY
=======
A 16-bit Windows application which uses the APPC, CPIC, or LUA interfaces may
hang when running over the SNA Server Windows 3.x client TCP/IP sockets
interface. This problem can occur on either WFW/Windows 3.x or Windows 95. This
problem may only occur when the client is configured for TCP/IP sockets. The
application may work correctly when the SNA Server Windows 3.x client is
configured to use named pipes or Netware ipx/spx.
There are two main scenarios where this has been observed:
1. If the 16-bit application isn't "peeking" on messages to all windows handles.
2. If the Windows SNA startup call is made from a different windows process than
the SNA API calls are made from.
These scenarios are described in more detail below.
NOTE: When running on Windows NT, a 16-bit Windows application that uses the
APPC, CPIC, or LUA interfaces can run over the SNA Server Windows NT client
software, through the 16-to-32-bit SNA "thunking" DLL's. By using these thunking
DLL's on the SNA Server Windows NT client software, the problems described in
this article do not occur.
MORE INFORMATION
================
Normally, a 16-bit Windows application which uses the SNA Server Windows 3.x SNA
API's should function properly regardless of the LAN interface used by the
underlying SNA Windows 3.x client software. However, the application may
encounter problems when running over the SNA client when configured for TCP/IP
sockets because the underlying architecture of the socket interface has special
requirements for the 16-bit Windows calling application.
If a 16-bit Windows application fails to work on top of the SNA Windows client
TCP/IP sockets interface, here are the possible causes.
1. If the 16-bit application isn't "peeking" on messages to all Window handles.
Unlike named pipes and Netware IPX/SPX, the Windows 3.x TCP/IP socket
interface runs within the non-preemptive Windows architecture, underneath the
calling application. When the SNA Windows 3.x client makes calls to named
pipes or Netware IPX/SPX, which run outside of Windows, the network i/o is
accomplished with no requirements of the 16-bit Windows application.
However, when the SNA Windows 3.x client is configured for TCP/IP sockets, the
16-bit Windows application must "peek" on messages intended for any Windows
handle, in order for the underlying SNA client software to receive data from
the TCP/IP sockets interface.
So, in order for the Windows application to work over TCP/IP sockets, the
application's Windows message loop should be architected as follows:
/* get the next message if any */
if ( PeekMessage ( &msg, NULL, 0, 0, PM_NOREMOVE) ) {
if ( msg.message = WM_QUIT )
return FALSE; // let app process WM_QUIT
PeekMessage ( &msg, NULL, 0, 0, PM_REMOVE) ;
TranslateMessage (&msg) ;
DispatchMessage (&msg) ;
}
The second parameter passed to PeekMessage(), the Window handle (hWnd), must
be NULL in order for the underlying TCP/IP sockets interface to receive
messages on behalf of the application.
NOTE: If an API communication layer is being developed (for example, an
ODBC/DRDA driver), the developer may not have control over the architecture
of the calling application. If this is occurring, then the following strategy
can be used to function over TCP/IP sockets:
- When SNA client is running over Winsock it makes a hidden window with
class name "SNA Winsock". For the other transports, it's "SNA Server".
- During initialization of the API communication layer, call EnumWindows and
find one whose class starts with "SNA ".
- Establish an SNA blocking hook which dispatches messages only for this
window.
- Call OpenFile (IF_EXIST) on WINSOCK.DLL. If it exists, call
If not, do not call LoadLibrary since this will put a dialog on the screen
if it can't find the DLL.
- Call GetProcAddress for WSAStartup and WSASetBlockingHook, and set a
Winsock blocking hook that doesn't dispatch any messages.
2. If the Windows SNA startup call is made from a different windows process than
the SNA API calls are made from.
If a Windows application calls the APPC, CPIC or LUA interface, the
application should first call WinAPPCStartup, WinCPICStartup, or
WinRUIStartup/WinSLIStartup respectively. This startup call should be
performed when the Windows process first initializes, before initiating a
session over the SNA interface.
A hang has been observed if a Windows 3.x application calls WinAPPCStartup
from one Windows process, and then calls the APPC interface from another
Windows process. Later versions of the SNA Windows 3.x client software (3.0
and later) now allow a Windows 3.x application to invoke an APPC conversation
without first calling WinAPPCStartup. However, the application should still
call WinAPPCStartup. If an application calls WinAPPCStartup from one process,
and then calls APPC functions from another process, the application may hang
if TCP/IP sockets is being used.
To correct this problem, the WinAPPCStartup call should be moved to the
process which is actually using the APPC interface, or the WinAPPCStartup and
WinAPPCCleanup calls should be removed from the Windows application.
Additional query words:
======================================================================
Keywords :
Technology : kbAudDeveloper kbSNAServSearch kbSNAServ200 kbSNAServ400 kbSNAServ210 kbSNAServ211SP1 kbSNAServ211SP2 kbSNAServ300SP3 kbSNAServ300SP1 kbSNAServ400SP1 kbSNAServ400SP2 kbSNAServ400SP3 kbSNAServ300SP2 kbSNAServ300SP4
Version : WINDOWS:2.0,2.1,2.11 SP1;2.11 SP2,3.0 (all SP),4.0,4.0 SP1,4.0 SP2,4.0 SP3
Issue type : kbprb
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.
Copyright Microsoft Corporation 1986-2002.