KnowledgeBase Archive

An Archive of Early Microsoft KnowledgeBase Articles

View on GitHub

Q169414: Cluster Service May Stop After Failover

Article: Q169414
Product(s): Microsoft Windows NT
Version(s): WinNT:4.0
Operating System(s): 
Keyword(s): kberrmsg kbsetup
Last Modified: 09-AUG-2001

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Windows NT Server, Enterprise Edition version 4.0 
- Microsoft Cluster Server 
-------------------------------------------------------------------------------

SYMPTOMS
========

If you install Microsoft Cluster Server and shut down one of the nodes in the
cluster, the cluster service may fail with the following event codes in the
system event log:

- Event 1006

- Event 7023

- Event 1009

CAUSE
=====

When you shut down one of the cluster nodes, all resources should transition to
a surviving node in the cluster. If the shared SCSI bus loses termination, the
surviving node may not have access to the shared devices. As a result, the
surviving node may also fail and remove itself from the cluster -- only if the
quorum disk is inaccessible.

The cluster service requires access to a shared SCSI bus. The bus must be
terminated at all times. Some SCSI host adapters may provide termination only
while the computer has power. Thus, after powering off, termination may be lost.

RESOLUTION
==========

To alleviate this condition, supply external terminators for the bus or enable
constant termination of the adapter.

MORE INFORMATION
================

Incorrect cabling or termination of the shared SCSI bus may also trigger this
condition. Additionally, use of standard SCSI terminators with a Wide SCSI bus
may provide inadequate termination. Some older terminators do not terminate the
high bits on the Wide SCSI chain and may result in partial termination of the
SCSI bus. Consult your hardware vendor for proper cabling and termination.

For additional information, please see the following article(s) in the Microsoft
Knowledge Base:

  Q168094 Problems Attaching SCSI-2 Devices to SCSI-3 Adapter

Additional query words: MSCS
======================================================================
Keywords          : kberrmsg kbsetup 
Technology        : kbWinNTsearch kbWinNT400search kbWinNTSsearch kbWinNTSEntSearch kbWinNTSEnt400 kbWinNTS400search kbAudDeveloper kbClustServSearch
Version           : WinNT:4.0
Issue type        : kbprb

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.