Q167192: HOWTO: Create a Progress Indicator Using Threed Panel Control

Article: Q167192
Product(s): Microsoft FoxPro
Version(s): 
Operating System(s): 
Keyword(s): kbinterop kbole kbOOP kbvfp500 kbvfp600
Last Modified: 11-AUG-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Visual FoxPro for Windows, versions 5.0, 5.0a, 6.0 
-------------------------------------------------------------------------------

SUMMARY
=======

This article describes how to create a progress/status indicator using the
Threed Panel ActiveX control in Visual FoxPro.

MORE INFORMATION
================

You can use the Threed Panel ActiveX control to display plain or three-
dimensional text on a three-dimensional background. It can also present
progress/status information in a dynamically colored circle or bar with or
without showing percent.

Here is a listing of properties required to create a progress/status indicator:

- FloodPercent: returns the percentage of the painted area inside the Threed
  Panel when the panel is used as a status or progress indicator. This property
  is not available at design time. The FloodPercent property can be set to an
  integer value between 0 and 100.

- FloodType: Determines if and how the panel is used as a status or progress
  indicator. Here is a listing of all the available setting for FloodType
  property:

     0 (Default) None - Panel has no status bar capability and the
                        caption (if any) is displayed.
     1 - Left to right.
     2 - Right to left.
     3 - Top to bottom.
     4 - Bottom to top.
     5 - From the center outward in a widening circle.

  Threed Panel will be painted in a color base on the above setting, which is
  specified by the FloodColor property, as the FloodPercent property increases.

- FloodShowPct: Determines whether the current setting of the FloodPercent
  property will be displayed in the center of the panel when the panel is used
  as a status or progress indicator. The FloodType property setting has to be
  other than None in order to work. The FloodShowPct property can either set it
  to TRUE to show or FALSE to hide the FloodPercent property.

- FloodColor: returns the color used to paint the area when the Threed Panel is
  used as a status or progress indicator. The FloodType property setting has to
  be other than None in order to work.

The following example using a Timer control to simulate the progress/status
indicator:

NOTE: Before you run the example below, making sure you have the Threed Panel
ActiveX control installed(Windows\System\Threed32.ocx).

1. Create a .prg file and cut and paste the following code into the .prg:

        PUBLIC x
        x=CREATEOBJECT("progress")
        x.SHOW

        **************************************************
        *-- Class:        progress
        *-- ParentClass:  form
        *-- BaseClass:    form
        *
        DEFINE CLASS progress AS form

           Top = 0
           Left = 0
           Height = 198
           Width = 378
           DoCreate = .T.
           Caption = "Form1"
           Name = "Form1"

           ADD OBJECT timer1 AS Timer WITH ;
             Top = 9, ;
             Left = 18, ;
             Height = 23, ;
             Width = 23, ;
             Enabled = .F., ;
             Interval = 100, ;
             Name = "Timer1"

           ADD OBJECT command1 AS CommandButton WITH ;
             Top = 121, ;
             Left = 71, ;
             Height = 27, ;
             Width = 247, ;
             Caption = "Click Me to Begin Task", ;
             Name = "Command1"

           ADD OBJECT sspanel1 AS sspanel WITH ;
             Top = 27, ;
             Left = 28, ;
             Height = 72, ;
             Width = 328, ;
             Name = "sspanel1"

           ADD OBJECT command2 AS CommandButton WITH ;
             Top = 159, ;
             Left = 70, ;
             Height = 26, ;
             Width = 247, ;
             Caption = "Reset", ;
             Name = "Command2"

           PROCEDURE Init
             * Set the FloodType from Left to Right
             THISFORM.sspanel1.FloodType = 1
             * Initialize the FloodPercent to 0
             THISFORM.sspanel1.FloodPercent = 0
             THISFORM.sspanel1.FloodShowPct = .T. && Show the percent sign
           ENDPROC

           PROCEDURE timer1.Timer
             IF THISFORM.sspanel1.FloodPercent < 100
                THISFORM.sspanel1.FloodPercent = ;
                   THISFORM.sspanel1.FloodPercent + 1
             ELSE
                THISFORM.timer1.Enabled = .F.
                THISFORM.command1.Caption = "Click Me to Begin Task"
                WAIT WINDOW "Task Completed"
                THISFORM.sspanel1.FloodPercent = 0
             ENDIF
           ENDPROC

           PROCEDURE command1.Click
             IF THIS.Caption = "Click Me to Begin Task"
                THIS.Caption = "Click Me to Stop Task"
                THISFORM.timer1.Enabled = .T.
             ELSE
                THIS.Caption = "Click Me to Begin Task"
                THISFORM.timer1.Enabled = .F.
             ENDIF
           ENDPROC

           PROCEDURE command2.Click
             THISFORM.Timer1.Enabled = .F.
             THISFORM.sspanel1.FloodPercent = 0
             THISFORM.Command1.Caption = "Click Me to Begin Task"
           ENDPROC

        ENDDEFINE

        DEFINE CLASS sspanel AS OLECONTROL

            OLEClass = "Threed.SSPanel"

        ENDDEFINE
        *
        *-- EndDefine: progress
        **************************************************

2. Run the .prg file and click the "Click Me to Begin Task" button, and the
  progress/status indicator appears in the Threed panel ActiveX control as
  FloodPercent property increases.

REFERENCES
==========

Custom Control Reference Help File (Ctrlref.hlp in the Windows\System or
WinNT\System32 folder if using Windows NT). This file may also appear in the
Visual FoxPro folder.

Additional query words:

======================================================================
Keywords          : kbinterop kbole kbOOP kbvfp500 kbvfp600 
Technology        : kbVFPsearch kbAudDeveloper kbVFP500 kbVFP600 kbVFP500a
Issue type        : kbhowto

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.