Q165088: CPIC Application Stops Responding When Starting Conversation
Article: Q165088
Product(s): Microsoft SNA Server
Version(s): WINDOWS:3.0
Operating System(s):
Keyword(s): kbnetwork
Last Modified: 13-JUN-2001
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft SNA Server, version 3.0
-------------------------------------------------------------------------------
SYMPTOMS
========
When you run a CPIC application on Windows 95, the CPIC application stops
responding intermittently when you try to acquire the conversation. Traces show
that the CM_Init request is not getting a response.
CAUSE
=====
This problem occurs if both of the following conditions are true:
- The CPIC application calls WinCPICCleanup() while there are pending RPC
requests.
-and-
- The RPC response arrives before SNAKRNL has closed all connections.
The following is a call to WinAPPCCleanup. Under the covers, there are still
outstanding rpc requests:
APPC WinAPPCCleanup response, result = TRUE
CPIC ---------------------------------------------- 09:34:42.49
CPIC WinCPICCleanup response, result = TRUE
CPIC ---------------------------------------------- 09:34:42.99
CPIC WinCPICStartup request
CPIC
CPIC Version Requested = 1.0
APPC ---------------------------------------------- 09:34:42.99
APPC WinAPPCStartup request
APPC
APPC Version Requested = 1.0
APPC ---------------------------------------------- 09:34:42.99
APPC WinAPPCStartup response, result = OK
APPC
APPC Version Supported = 1.0
CPIC ---------------------------------------------- 09:34:42.99
CPIC WinCPICStartup response, result = OK
CPIC
CPIC Version Supported = 1.0
The following is a request to start the conversation. There is no return to the
CMNIT() CPIC call:
CPIC ---------------------------------------------- 09:34:43.10
CPIC CMINIT request
CPIC Sym dest name = QR27
APPC ---------------------------------------------- 09:34:43.10
APPC TP_STARTED request
APPC
APPC Type:Sync VerbID:00001800
APPC
APPC ---- Verb Parameter Block at address 01300000 ----
APPC 14000000 00000000 00000000 00000000 <................>
APPC 00000000 00000000 F80B5800 C3D7C9C3 <........8.X.CPIC>
APPC 6DC4C5C6 C1D3E36D E3D72020 20202040 <mDEFALTmTP @>
APPC 40404040 40404040 40404040 40404040 <@@@@@@@@@@@@@@@@>
APPC 40404040 40404040 40404040 40404040 <@@@@@@@@@@@@@@@@>
APPC 40404040 40404040 40404040 <@@@@@@@@@@@@ >
RESOLUTION
==========
To resolve this problem, obtain the hotfix mentioned below. With the hotfix,
SNAKRNL now ignores all RPC responses that arrive after WinCPICCleanup() or
WinAPPCCleanup().
STATUS
======
Microsoft has confirmed this to be a problem in SNA Server version 3.0. This
problem was corrected in the latest Microsoft SNA Server 3.0 U.S. Service Pack.
For information on obtaining the service pack, query on the following word in
the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words: prodsna
======================================================================
Keywords : kbnetwork
Technology : kbAudDeveloper kbSNAServSearch kbSNAServ300
Version : WINDOWS:3.0
Issue type : kbbug
Solution Type : kbfix
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.
Copyright Microsoft Corporation 1986-2002.