Q165017: Description of Event ID 9302

Article: Q165017
Product(s): Microsoft Exchange
Version(s): winnt:4.0,5.0,5.5
Operating System(s): 
Keyword(s): kbusage exc4 exc5 exc55
Last Modified: 19-DEC-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Exchange Server, versions 5.5, 4.0, 5.0 
-------------------------------------------------------------------------------


SUMMARY
=======

When you look through event logs, you might come across the following warning
message:

  Event id 9302

Description from the Infollog.cfg file from the Exchsrvr\Mtadata directory:

  The transport configuration type %1 for the directory entry %2 is not
  one of the supported values. Reconfigure the transport configuration
  type in the identified directory entry. [%3 %4 %5 %6] (8)

***************************************************************************
* MESSAGE DESCRIPTION: Bad Transport config
***************************************************************************
*
* MSG LABEL        INFOID    INFOTYPE  SEVERITY  COMMENT
*
SBCDBTRN           9302    W 7         8         Bad Transport config
*
* PARAMETER LABEL  PARMID  PARMTYP DIAGLEV MAXLEN  COMMENT
*
TRANTYPE           130     I       1       0       Transport type
TRANSDN            146     S       1       0       Entry DN
*
-          Bad transport config : type = %1 (see OTCSFIRE.C)
-            Entry DN %2

Sample warning message:

  The transport configuration type 1 for the directory entry
  /o=Microsoft/ou=Cartoonville/cn=Configuration/cn=Servers/cn=SAMEERP66
  /cn=Microsoft MTA is not one of the supported values. Reconfigure the
  transport configuration type in the identified directory entry.
  [BASE IL OPERATOR 34 217] (8)


The list for the transport types are as follows:

Type     0x01    stands for  RFC 1006
Type     0x02    stands for  TP4
Type     0x03    stands for  Eicon X.25
Type     0x04    stands for  Named pipes over RAS connection
Type     0x05    stands for  RPC

MORE INFORMATION
================

This warning message does not reflect any problems with Microsoft Exchange
Server. Look at other warnings and/or errors associated with this warning for
more troubleshooting information.

Additional query words:

======================================================================
Keywords          : kbusage exc4 exc5 exc55 
Technology        : kbExchangeSearch kbExchange500 kbExchange550 kbExchange400 kbZNotKeyword2
Version           : winnt:4.0,5.0,5.5
Issue type        : kbinfo

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.