Q162696: PowerPC WINS Server Shows the Domain
Article: Q162696
Product(s): Microsoft Windows NT
Version(s): winnt:3.51,4.0
Operating System(s):
Keyword(s): kbnetwork
Last Modified: 09-AUG-2001
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Windows NT Server versions 3.51, 4.0
-------------------------------------------------------------------------------
SYMPTOMS
========
A network client is unable to browse computers that reside on the primary domain
controller's (PDC's) own segment by means of File Manager or Network
Neighborhood. All other segments are visible and can be browsed. However, the
client is able to connect to any computer on the PDCs segment, as long as the
server name is known.
CAUSE
=====
The PDC for the domain is also running Windows Internet Name Service (WINS), and
that server is on the PowerPC, MIPS, or Alpha platforms. If nbtstat -n is run
from the PDC, it will show that the domainname<1D> is in conflict. This
happens when a segment master browser for the domain (on a different segment
than the PDC) releases its names during a shutdown. When that computer releases
the domainname<1D>, the WINS server/PDC logs a duplicate name error, and
shows its own <1D> entry to be in conflict. If the domainname<1D>
name is not registered in the WINS database, the WINS server will always discard
that entry. But, it is necessary for the name to be registered by means of NetBT
(the NetBIOS interface on TCP/IP), as that is the name that the server listens
to and mailslot browser broadcasts on.
For additional information, please see the following articles in the Microsoft
Knowledge Base:
ARTICLE-ID: Q119493
TITLE : NetBIOS over TCP/IP Name Resolution and WINS
ARTICLE-ID: Q119495
TITLE : List of Names Registered with WINS Service
ARTICLE-ID: Q120151
TITLE : Browsing a Wide Area Network with WINS
RESOLUTION
==========
To resolve this issue, perform one of the following:
- Move the WINS service off of the PDC to another server.
-or-
- Run your PDC/WINS server on a different platform, for example, Intel.
-or-
- For Windows NT 4.0, obtain the latest service pack, but for Windows NT 3.51
obtain the hotfix mentioned below.
STATUS
======
Microsoft has confirmed this to be a problem in Windows NT versions 3.51 and
4.0. This problem was corrected in the latest Microsoft Windows NT 4.0 U.S.
Service Pack. For information on obtaining the service pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words:
======================================================================
Keywords : kbnetwork
Technology : kbWinNTsearch kbWinNT351search kbWinNT400search kbWinNTSsearch kbWinNTS400search kbWinNTS400 kbWinNTS351 kbWinNTS351search
Version : winnt:3.51,4.0
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.
Copyright Microsoft Corporation 1986-2002.