KnowledgeBase Archive

An Archive of Early Microsoft KnowledgeBase Articles

View on GitHub

Q160978: Terminal Type Negotiation Fails w/RUMBA v3.2J TN3270 Emulator

Article: Q160978
Product(s): Microsoft SNA Server
Version(s): WINDOWS:2.0,2.1,2.11,2.11 SP1
Operating System(s): 
Keyword(s): kb3rdparty kbnetwork
Last Modified: 12-JUN-2001

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft SNA Server, versions 2.0, 2.1, 2.11, 2.11 SP1 
-------------------------------------------------------------------------------


SYMPTOMS
========

When you attempt to connect to SNA Server's TN3270/e service with the Wall Data
RUMBA v3.2J TN3270 emulator, you may see the following errors on the emulator:

  Terminal Type Negotiation failure

  -and-

  Communication error 501

CAUSE
=====

The Wall Data RUMBA v3.2J TN3270 emulator sends a message that is out of the
normal sequence, but still legal. This causes the TN3270E Server to renegotiate
an option it had already negotiated.

The TN3720 negotiation would never complete if the emulator sent a "Won't
TN3270E" command after it had sent a "Will TERMTYPE" command. This is because
the TN3270 Server sends a "Do TERMTYPE" command in response to the "Won't
TN3270E" command, even though the emulator had already sent the "Will TERMTYPE"
command.

RESOLUTION
==========

To resolve this problem, obtain the hotfix mentioned below. If the emulator
sends "Will TERMTYPE" before the "Won't TN3270E," the TN3270/e Service doesn't
send a "Do TERMTYPE."

STATUS
======

Microsoft has confirmed this to be a problem in SNA Server versions 2.0, 2.1,
2.11, and 2.11 Service Pack 1. This problem was corrected in the latest
Microsoft SNA Server 2.11 U.S. Service Pack. For information on obtaining the
service pack, query on the following word in the Microsoft Knowledge Base
(without the spaces):

  S E R V P A C K


MORE INFORMATION
================

The following is an example of a normal case:

TN3270/e Service Emulator
-------------------------

  Do TN3270E
  Won't TN3270E
  Do TERMTYPE
  Will TERMTYPE

The following is an example of a failing case with the Wall Data RUMBA v3.2J
TN3270:

TN3270/e Service Emulator
-------------------------

  Do TN3270E
  Will TERMTYPE
  Won't TN3270E
  Do TERMTYPE

Additional query words: prodsna

======================================================================
Keywords          : kb3rdparty kbnetwork 
Technology        : kbAudDeveloper kbSNAServSearch kbSNAServ200 kbSNAServ211 kbSNAServ210 kbSNAServ211SP1
Version           : WINDOWS:2.0,2.1,2.11,2.11 SP1
Issue type        : kbbug
Solution Type     : kbfix

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.