SYMPTOMS
========

You have a Microsoft Exchange Server Organization configured with multiple Sites
connected by X.400 connectors, and each Site has a Microsoft Mail Connector
servicing the same set of Microsoft Mail postoffices. The Microsoft Mail
Connectors have a size limit imposed but the X.400 connector does not.

You send a message that exceeds the size limit, but it is a long time, perhaps
several hours, before you receive a non-delivery report (NDR).

CAUSE
=====

A message that exceeds the size limit should result in an immediate NDR;
however, because the routing table has an alternate route over the X.400
connector to the other site, the message transfer agent (MTA) reroutes the
message until it reaches the hard-coded hop count of 512.

A message will go through the 512-hop count before returning an NDR if a
particular user is restricted from using all the connectors of a particular type
(for example, all IMCs in an organization). A restricted user may not receive an
NDR for hours (depending on the Microsoft Exchange Server topology).

This behavior is by design for Microsoft Exchange Server. The Microsoft Exchange
Message Transfer Agent (MTA) does not store detailed data about each reroute in
the P1 header of each message that passes through the MTA. This could
potentially make individual messages much larger because each time they pass
through another MTA, the Internal-Trace-Information-Element would significantly
grow in size. This could severely degrade MTA performance. The P1 header of a
message passing through the MTA only contains destination MTA name, hop count,
and routing action information.

WORKAROUND
==========

To work around this problem, do one of the following:

- Have a consistent size limit for the organization. Set this on the MTA object
  of the server objects.

- Eliminate redundant paths to the same destination. (Have only one Microsoft
  Mail Connector servicing that set of postoffices).

STATUS
======

This behavior is by design as stated for Exchange Server.

Additional query words: loop message tracking restrictions

======================================================================
Keywords          : exc4 exc5 exc55 
Technology        : kbExchangeSearch kbExchange500 kbExchange550 kbExchange400 kbZNotKeyword2
Version           : winnt:4.0,5.0,5.5
Issue type        : kbinfo

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.