Q152304: Random Blue Screens Caused by Bad Packet and DLC.SYS

Article: Q152304
Product(s): Microsoft Windows NT
Version(s): 3.51
Operating System(s): 
Keyword(s): kbnetwork
Last Modified: 08-AUG-2001

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Windows NT Workstation version 3.51 
- Microsoft Windows NT Server version 3.51 
-------------------------------------------------------------------------------


SYMPTOMS
========

A Windows NT STOP Message (Blue Screen), frequently a BugCheck 0x0000000A, is
displayed due to a corrupt Ethernet 802.3 packet received by DLC.SYS.

CAUSE
=====

An assumption was made by DLC.SYS that a Length Field (LPDU Length) in the 802.3
Ethernet header was valid. This length field should always be 3 or greater.

An IEEE 802.3 Frame has the following format.

|<------------------ Maximum Length 1532 Bytes ------------------>|
V                                                                 V
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-//--+-+-+-+-+-+-+-+
|  PREAMBLE   |S| DEST ADDR | SRC ADDR  |LP | LPDU  |Pad  |  FCS  |
|  7 Bytes    |D|  6 Bytes  |  6 Bytes  |DU | Bytes |     |4 Bytes|
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-//--+-+-+-+-+-+-+-+
                                               |
                                               |
                                /--------------/ 
     |                          |                        |
     V                          V                        V
   <-+--------+--------+--------+--------+-------//------+>
     |  DSAP  |  SSAP  |  Control Field  | Information   |
     | 1 Byte | 1 Byte |  1 or 2 Bytes   |  Field        |
   <-+--------+--------+--------+--------+-------//------+>

                    IEEE 802.3 Frame Format

The field lengths are as follows:

    * Preamble - 7 bytes
    * Start Delimiter (SD) - 1 byte
    * Destination Address (DEST ADDR)- 6 bytes
    * Source Address (SRC ADDR) - 6 bytes
    * LPDU Length (Length of the LLC Protocol Data Unit) - 2 bytes
      (This field should always have a value of 3-1500)
    * LPDU (LLC Protocol Data Unit) - variable length (3-1500 bytes)
      - Destination SAP Address (DSAP) - 1 byte
      - Source SAP Address (SSAP) - 1 byte
      - Control Field - 1 or 2 bytes
      - Informational Field - variable length (0-1497)
    * Pad - 0 to 43 bytes
    * Frame Check Sequence (FCS) - 4 bytes

In the case that caused the Windows NT STOP Message, a corrupt IEEE 802.3 frame
was received by DLC.SYS with a LPDU Length field of 0 (which is invalid).
Because every LLC Protocol Data Unit (LPDU) consists of a 1 byte DSAP, 1 byte
SSAP, and at least a 1 byte Control Field, the LPDU Length should always be at
least 3.


RESOLUTION
==========

A change was made to DLC.SYS to inspect the LPDU Length field and to discard all
IEEE 802.3 packets whose length fields are invalid (less than 3).


STATUS
======

Microsoft has confirmed this to be a problem in Windows NT version 3.51. This
problem was corrected in the latest Windows NT 3.51 U.S. Service Pack. For
information on obtaining the Service Pack, query on the following word in the
Microsoft Knowledge Base (without the spaces):

  S E R V P A C K


Additional query words: prodnt Instability Pool Memory Corruption

======================================================================
Keywords          : kbnetwork 
Technology        : kbWinNTsearch kbWinNTWsearch kbWinNT351search kbWinNTW351search kbWinNTW351 kbWinNTSsearch kbWinNTS351 kbWinNTS351search
Version           : 3.51

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.