Q141558: FIX: WindowType Changed at Run Time Can’t Be Changed Back

Article: Q141558
Product(s): Microsoft FoxPro
Version(s): WINDOWS:3.0,3.0b
Operating System(s): 
Keyword(s): kbbuglist
Last Modified: 24-MAR-2000

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Visual FoxPro for Windows, versions 3.0, 3.0b 
-------------------------------------------------------------------------------

SYMPTOMS
========

You attempt to change the WindowType of a running form from modeless to modal
and then back to modeless. On the switch from modeless to modal, you succeed.
But the attempt to switch the now modal form to modeless fails.

WORKAROUND
==========

Although there isn't much call to do this at run time, the switch is one way
only. There is no way to programmatically change it back.


STATUS
======

Microsoft has confirmed this to be a problem in the Microsoft products listed at
the beginning of this article. This problem has been fixed in Visual FoxPro 5.0.

MORE INFORMATION
================

The WindowType of a form should be a property you set a design time; not run
time.

Steps to Reproduce Problem
--------------------------

1. Create a new form, and set the form's WindowType property to Modeless.

2. Place a command button on the form. In the Click method, add the following
  line of code:

        THISFORM.SHOW(1)

3. Change the Caption property to Modal. Place a second command button on the
  form, and add the following code to its Click event:

        THISFORM.SHOW(2)

4. Change the Caption property to Modeless. Place a third command button on the
  form. Change its Caption property to Release, and add the following code to
  its Click event:

        THISFORM.RELEASE

5. Run the form. If you click the Release command button, the form closes as
  expected. If you click the Modal command button, the form becomes modal. You
  may test this by trying to click outside of the form and noting you are
  unable to activate anything outside of the form or access any other part of
  the Windows interface. If you then click the Modeless command button, the
  form does not return to a modeless WindowType. The form remains modal. The
  Release command button does not release the form. You must cancel the program
  to exit.


Additional query words: VFoxWin buglist3.00 buglist3.00b kbvfp300 kbvfp300b kbVfp500fix

======================================================================
Keywords          :  kbbuglist
Technology        : kbVFPsearch kbAudDeveloper kbVFP300 kbVFP300b
Version           : WINDOWS:3.0,3.0b
Issue type        : kbbug
Solution Type     : kbfix

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.