Q139378: Debugging SNA Server Application Exceptions on WinNT 3.5 & 3.51

Article: Q139378
Product(s): Microsoft SNA Server
Version(s): WINDOWS:2.0,2.1,2.11,3.0,3.0 SP1,3.0 SP2,3.0 SP3,4.0,4.0 SP1,4.0 SP2,4.0 SP3; winnt:3.5
Operating System(s): 
Keyword(s): kbinterop kbnetwork kbsetup
Last Modified: 13-JUN-2001

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft SNA Server, versions 2.0, 2.1, 2.11, 3.0, 3.0 SP1, 3.0 SP2, 3.0 SP3, 4.0, 4.0 SP1, 4.0 SP2, 4.0 SP3, on platform(s):
   - the operating system: Microsoft Windows NT 
- Microsoft Windows NT Workstation versions 3.5, 3.51 
- Microsoft Windows NT Server versions 3.5, 3.51 
-------------------------------------------------------------------------------

SUMMARY
=======

This article gives you the following information for debugging SNA Server
application exceptions on your computer running Windows NT 3.5 and 3.51:

- Entries in SNA Dump File, Application Event Log, and DRWATSON.LOG

- DRWTSN32.EXE Specified as Default Debugger in Registry

- DRWTSN32.EXE Can Fail

- How to Configure SNA Server for Debugging

- Information to Provide to SNA Server Support Team

- SNA Server 2.11 README.WRI File Excerpt

MORE INFORMATION
================

Entries in Dump File, Application Event Log, and DRWATSON.LOG
-------------------------------------------------------------

If an application exception or unexpected internal error occurs in an SNA Server
component, SNA Server automatically generates an application dump file
containing the memory contents of the failing process. Also, SNA Server logs the
following event in the Windows NT Application event log:

  Event: 624
  Creating dump file <filename> for <process>

If the dump file is due to an unexpected internal error in SNA Server, this error
is logged at the same time as Event 624. In such cases, the DRWTSN32.LOG
indicates a hardcoded breakpoint. For example:

  Application exception occurred in module <modulename>
  Exception number: 80000003 (hardcoded breakpoint)

The DRWTSN32.LOG is important to diagnose the cause of the failure.

DRWATSN32.EXE Specified as Default Debugger in Registry
-------------------------------------------------------

On Windows NT 3.5 and 3.51, DRWTSN32.EXE is the default debugger that gets
invoked if an application exception occurs. This is set in the Windows NT
registry under the HKEY_LOCAL_MACHINE subtree under the following key:

  \SOFTWARE\Microsoft\Windows NT\CurrentVersion\AeDebug\ 

The following parameters appear in the right window of the Registry Editor:

  Auto: REG_SZ: 1

  Debugger:REG_SZ: drwtsn32 -p %ld -e %ld -g

NOTE: If Auto is set to 1 (one), the debugger runs immediately. If Auto is set to
0 (zero), then you must choose Cancel at the Windows NT application exception
screen to invoke the debugger.

NOTE: "l" in "%ld" is the letter "l" and not the number one (1).

DRWATSN32.EXE Can Fail
----------------------

When you run Windows NT 3.5, the following problems can cause DRWTSN32.EXE to
fail to generate a useful DRWTSN32.LOG file:

- The Windows NT 3.5 symbols have not already been copied to the
  <ntroot>\symbols tree.

- You use SNA Server 2.1 or 2.11, and the failure has occurred in a component
  that was built using full compiler optimizations.

  NOTE: SNA Server 2.11 ships non-optimized versions of the SNA binaries to
  support reliable DRWTSN32.LOG generation on computers running Windows NT 3.5.
  However, a useful DRWTSN32.LOG may still be generated without applying these
  non-optimized binaries.


How to Configure SNA Server for Debugging
-----------------------------------------

When you run SNA Server 2.1 on Windows NT 3.5:

- Apply Windows NT symbols.

When you run SNA Server 2.11 on Windows NT 3.5:

- Apply Windows NT symbols.

- Run SETUPDBG/MAKEDBG as documented in the 2.11 README.TXT file.

When you run SNA Server 2.1 or 2.11 on Windows NT 3.51:

- It is not necessary to run SETUPDBG/MAKEDBG, as documented in the 2.11
  Readme.txt file and Readdbg.txt file. Also, when running on Windows NT 3.51,
  it is not necessary to copy Windows NT 3.51 symbols, due to an enhancement in
  the Windows NT 3.51 version of Drwtsn32.exe.

When you run SNA Server 3.0 on Windows NT 3.51:

- Verify that the symbols from the 3.0 CD were applied. Default installations
  should copy the symbols over to the <winntroot>\SYMBOLS tree.

When you run SNA Server 2.11 with Service Pack 1 (SP1) installed:

- The SNA Server 2.11 Service Pack 1 symbols are included in the
  self-extracting SP1 server update file (for each platform), though the
  symbols are not automatically installed when the Service Pack 1 update
  program is run. Matching symbols must be present in the server computer
  <ntroot>\SYMBOLS directory tree or the DRWTSN32.LOG entry does not show
  valid stack information.

- To manually install the symbols, run XCOPY to copy the \SYMBOLS directory
  from the SNA Server 2.11 SP1 self-extracting file to the Windows NT root
  directory. For example:

  xcopy <sp1root>\SYMBOLS\*.* <winntroot>\SYMBOLS /s /e /v

Information to Provide to SNA Server Support Team
-------------------------------------------------

If an application exception occurs in an SNA Server component, provide the
following information to the SNA Server support team:

- <ntroot>\DRWTSN32.LOG.

- <snaroot>\TRACES\SNADUMP.LOG.

- Windows NT System and Application event logs.

- SNA Server configuration file (<snaroot>\SYSTEM\CONFIG\COM.CFG).

SNA Server 2.11 README.WRI File Excerpt
---------------------------------------

The following is an excerpt from the SNA Server 2.11 README.WRI file that is
installed in the SNA Server group icon:

A.5. Notes on obtaining useful DRWTSN32.LOG files

By default, the log files generated by the Dr. Watson utility do not contain
symbol information necessary for interpreting those files. This is because SNA
Server components contain optimized instructions that prevent the Dr. Watson
utility from being able to provide a full trace. In addition, the default
configuration of Windows NT version 3.5 does not include symbol information
required by the Dr. Watson utility.

If you are experiencing a Windows NT trap, and if Microsoft Product Support
Services requests a copy of your DRWTSN32.LOG file, you must modify your system
setup before the Dr. Watson utility can produce a useful log file the next time
a trap occurs.

For a computer running Windows NT Server version 3.5, you must perform the
following steps to make symbol information available to the Dr. Watson utility:

1. Place the Windows NT installation CD-ROM in the CD-ROM drive.

2. At the Windows NT command prompt, execute the following command:

  "xcopy <cd_drive>:\support\debug\<cpu_type>\symbols\*.*
  %systemroot%\symbols\*.* /s /e /v" (without the quotation marks)

If any Windows NT service packs have been applied, copy the symbols supplied with
the service pack in the same manner.

On all versions of Windows NT, you must replace all SNA Server system files with
debug versions using this procedure:

1. Place the SNA Server CD-ROM in the CD-ROM drive.

2. At the Windows NT command prompt, execute the following commands:

  " cd_drive:
  cd \
  setupdbg
  snaroot_drive:
  cd %snaroot%
  makedbg cd_drive:" (without the quotation marks)

  Cd_drive is the drive letter or UNC path of the drive containing the SNA
  Server CD-ROM.snaroot_drive is the drive letter of the drive on the server
  that contains the SNA Server system directory.

  This step creates two subdirectories in the SNA Server system directory: DEBUG
  contains nonoptimized, debug versions of the SNA Server system files, while
  NODEBUG contains copies of the original, optimized SNA Server system files.

3. To prepare the system for troubleshooting with the Dr. Watson utility,
  execute the following commands:

  "net stop snaserver
  net stop snabase
  copy %snaroot%\debug %snaroot%" (without the quotation marks)

4. Restart the system.

When you no longer need to run the debug versions of the SNA Server system files,
execute the following commands and then restart the system:

  "net stop snaserver
  net stop snabase
  copy %snaroot%\nodebug %snaroot%" (without the quotation marks)

Additional query words: prodsna

======================================================================
Keywords          : kbinterop kbnetwork kbsetup 
Technology        : kbAudDeveloper kbSNAServSearch
Version           : WINDOWS:2.0,2.1,2.11,3.0,3.0 SP1,3.0 SP2,3.0 SP3,4.0,4.0 SP1,4.0 SP2,4.0 SP3; winnt:3.5,3.51
Issue type        : kbhowto

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.