Q135611: FIX: Try to Modify Label Previewed by Another, Calls Converter

Article: Q135611
Product(s): Microsoft FoxPro
Version(s): WINDOWS:3.0,3.0b
Operating System(s): 
Keyword(s): kbvfp kbvfp300bBUG kbvfp500fixkbbuglist kbfixlist
Last Modified: 24-MAR-2000

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Visual FoxPro for Windows, versions 3.0, 3.0b 
-------------------------------------------------------------------------------

SYMPTOMS
========

When a label form is shared and one workstation attempts to modify the form
while another has run the label in preview mode, the converter is erroneously
called.

WORKAROUND
==========

The error condition is harmless, but you should cancel the Converter dialog box,
and postpone the attempt to modify the label until after the other workstation
has completed previewing the label.

STATUS
======

Microsoft has confirmed this to be a problem in the Microsoft products listed at
the beginning of this article. This problem has been fixed in Visual FoxPro 5.0
for Windows.

When the label is modified from the second workstation in Visual FoxPro 5.0, a
"File access is denied" message appears.

MORE INFORMATION
================

While a label form can be both modified and printed simultaneously, attempting
to run the label in preview mode synchronously results in the error "File access
is denied." Unlike the Label Designer, the Report Designer correctly returns
this error when you attempt to modify a report that is already being previewed
by another. In all cases, previewing must be completed before a label or report
can be shared again in any other operation.

Steps to Reproduce Problem
--------------------------

1. On one workstation, create a label, and issue this command:

     LABEL FORM <labelname> PREVIEW

2. On the second workstation, connect to the same directory in which the label
  was created, and attempt to modify it:

     MODIFY LABEL <labelname>

3. Choose Cancel when the Converter dialog box appears.

Additional query words: 3.00 3.00b

======================================================================
Keywords          : kbvfp kbvfp300bBUG kbvfp500fix kbbuglist kbfixlist
Technology        : kbVFPsearch kbAudDeveloper kbVFP300 kbVFP300b
Version           : WINDOWS:3.0,3.0b
Issue type        : kbbug
Solution Type     : kbfix

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.