Q128796: Running After Dark: Unable to Access Serial and Parallel Ports
Article: Q128796
Product(s): Microsoft Windows NT
Version(s):
Operating System(s):
Keyword(s):
Last Modified: 08-AUG-2001
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Windows NT Server version 3.1
- Microsoft Windows NT Workstation version 3.1
- Microsoft Windows NT Advanced Server, version 3.1
- Microsoft Windows NT Workstation version 3.5
- Microsoft Windows NT Server version 3.5
-------------------------------------------------------------------------------
SYMPTOMS
========
When After Dark version 2.0 loads in Windows NT and you attempt to start an
application that uses a device connected to a serial communication (COM) port,
the following error message appears:
The selected COM port is either not supported or is being used by another
device.
Select another port.
If you select another port, the same error message appears again.
CAUSE
=====
This problem occurs when After Dark 2.0 SystemIQ Activity Monitor runs before
you start the application using the COM ports.
SystemIQ Activity Monitor monitors serial and parallel port activity as well as
CPU load. As activity of the CPU or external devices increases, After Dark does
not blank out the screen to provide maximum processing time to other tasks.
WORKAROUND
==========
To work around this problem:
1. Run the After Dark Control program and choose Setup.
2. Clear the SystemIQ Activity Monitor check box.
3. Using a text editor, open the AD_PREFS.INI file. This file is located at the
Windows NT %SystemRoot% directory.
4. In the [After Dark] section of AD_PREFS.INI, change "WatchComPorts=1,2,3,4"
to ";WatchComPorts=1,2,3,4" (without the quotation marks).
NOTE: If one specific COM port is used by the COM device continuously, such as
Terminal or Remote Access Service), remove only the port number. You do not
have to remark out (;) the entire line.
5. If you experience problems with the parallel ports, change the
"WatchParallelPorts=1,2,3" entry in the [After Dark] section of AD_PREFS.INI
file to ";WatchParallelPorts=1,2,3" (without the quotation marks).
NOTE: If one specific parallel port is used by a parallel device continuously,
remove only the port number. You do not have to remark out (;) the entire
line. The problem with parallel ports does not cause the message above to
appear.
The product discussed here is manufactured by Berkeley Systems, Inc., a vendor
independent of Microsoft; we make no warranty, implied or otherwise, regarding
these products' performance or reliability.
Additional query words: 3.10 ad prodnt
======================================================================
Keywords :
Technology : kbWinNTsearch kbWinNTWsearch kbWinNT350search kbWinNTW350 kbWinNTW350search kbWinNTW310 kbWinNTSsearch kbWinNTS350 kbWinNTS310 kbWinNTAdvSerSearch kbWinNTAdvServ310 kbWinNTS350search kbWinNTS310search kbWinNT310Search kbWinNTW310Search
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.
Copyright Microsoft Corporation 1986-2002.