Q128335: IPX Subnet Clients Unable to Connect to Windows NT
Article: Q128335
Product(s): Microsoft Windows NT
Version(s): 3.11,3.5
Operating System(s):
Keyword(s):
Last Modified: 06-FEB-2002
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Windows NT Workstation version 3.5
- Microsoft Windows NT Server version 3.5
- Microsoft Windows for Workgroups version 3.11
-------------------------------------------------------------------------------
SYMPTOMS
========
When IPX clients from a subnet attempt to connect to a server, the following
error message appears:
DOS error 53 - name not found
CAUSE
=====
This problem occurs if the connection request originates from a client whose IPX
four byte network number contains 06 in the second byte. The server responds
with a name recognized to a FindName Query from any other network excluding the
range mentioned above.
When the NBIPX portion of the code receives the frame, it checks certain frame
properties. If the second byte in the NBIPX header is 06, it assumes it is a
session data frame. As a result, NameRecognize is not processed.
The following is a sample FindName frame that does not get a response:
NOTE: TransmissionControl is set to 1 (indicating 1 hop). Second byte in the
NBIPX header contains 00 06. The network number in the IPX header (x6112) is not
the same in the NBIPX portion. This is a modified FindName frame that was
transmitted on the wire using Network Monitor.
USER1STA *BROADCAST NBIPX Find Name USER101 <00>
ETHERNET: 802.3 Length = 98
IPX: NetBIOS Packet - 6112.08002B314A12.455 -> 0.FFFFFFFFFFFF.455 - 1 Hops
IPX: Checksum = 65535 (0xFFFF)
IPX: IDP Length = 80 (0x50)
IPX: Transport control = 1 (0x1)
IPX: Packet type = WAN Broadcast
IPX: Destination Address Summary 0.FFFFFFFFFFFF.455
IPX: IPX Address = 00000000.FFFFFFFFFFFF
IPX: Destination Net Number = 0 (0x0)
IPX: Destination Socket Number = NetBIOS
IPX: Source Address Summary 6112.08002B314A12.455
IPX: IPX Address = 00006112.08002B314A12
IPX: Source Net Number = 24850 (0x6112)
IPX: Source Socket Number = NetBIOS
IPX: Data: Number of data bytes remaining = 50 (0x0032)
NBIPX: Find Name USER101 <00>
NBIPX: Routing Info
NBIPX: Routing information = 393216 (0x60000)
NBIPX: Routing information = 0 (0x0)
NBIPX: Routing information = 0 (0x0)
NBIPX: Routing information = 0 (0x0)
NBIPX: Routing information = 0 (0x0)
NBIPX: Routing information = 0 (0x0)
NBIPX: Routing information = 0 (0x0)
NBIPX: Routing information = 0 (0x0)
NBIPX: Name type flag
NBIPX: 0....... = Unique Name
NBIPX: .0...... = Name not used
NBIPX: .....0.. = Name not Registered
NBIPX: ......0. = Name not Duplicated
NBIPX: .......0 = Name not Deregistered
NBIPX: Data stream type 2 = Find Name
NBIPX: Name = USER101 <00>
NBIPX: Data: Number of data bytes remaining = 1 (0x0001)
00000: FF FF FF FF FF FF 08 00 2B 31 4A 12 00 54 E0 E0 ........+1J..T..
00010: 03 FF FF 00 50 01 14 00 00 00 00 FF FF FF FF FF ....P...........
00020: FF 04 55 00 00 61 12 08 00 2B 31 4A 12 04 55 00 ..U..a...+1J..U.
00030: 06 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
00040: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
00050: 01 4D 4F 48 41 4B 30 31 20 20 20 20 20 20 20 20 .USER101
00060: 00 00 ..
Source: private\ntos\tdi\isn\nb\Receive.c
routine nbireceive()
if((PacketSize >= sizeof(NB_CONNECTION)) &&
(NbFrame->Connection.Session.DataStreamType== NB_CMD_SESSION_DATA))
{
NbiProcessSessionData();
} else {
<BR/><BR/>
if (NbFrame->Connectionless.IpxHeader.PacketType == 0x14)
{
DataStreamType= NbFrame->Connectionless.NameFrame.DataStreamType2;
}
else
{ DataStreamType= NbFrame->Connectionless.NameFrame.DataStreamType;
.....
Debugging info:
Setting a break point at nwlnknb!_NbiReceive and stepping thro
thro the code when it hits the break point:
fcd975f1 8b4c2418 mov ecx,[esp+0x18]
fcd975f5 6681791c0455 cmp word ptr [ecx+0x1c],0x5504 <<NB_SOCKET
fcd975fb 8bec mov ebp,esp
fcd975fd 0f85b7000000 jne nwlnknb!_NbiReceive+0xca (fcd976ba)
fcd97603 a138bbd9fc mov eax,[nwlnknb!_NbiDevice (fcd9bb38)]
fcd97608 ff804c040000 inc dword ptr [eax+0x44c]
fcd9760e 8b4524 mov eax,[ebp+0x24]
fcd97611 83f830 cmp eax,0x30 << check for size of frame
fcd97614 7224 jb nwlnknb!_NbiReceive+0x4a (fcd9763a)
Problem occurs here !!
fcd97616 80791f06 cmp byte ptr [ecx+0x1f],0x6 <<sessiondata ???
fcd9761a 751e jnz nwlnknb!_NbiReceive+0x4a (fcd9763a)
fcd9761c 50 push eax
fcd9761d ff7520 push dword ptr [ebp+0x20]
fcd97620 ff751c push dword ptr [ebp+0x1c]
fcd97623 51 push ecx
fcd97624 ff7514 push dword ptr [ebp+0x14]
fcd97627 ff7510 push dword ptr [ebp+0x10]
fcd9762a ff750c push dword ptr [ebp+0xc]
fcd9762d ff7508 push dword ptr [ebp+0x8]
fcd97630 e8171e0000 call nwlnknb!_NbiProcessSessionData
WORKAROUND
----------
To work around this problem, use an IPX network number that does not have 06 as
the second byte in the network number.
STATUS
------
Microsoft has confirmed this to be a problem in Windows NT version 3.5. This
problem has been corrected in the latest U.S. Service Pack for Windows NT
version 3.5. For information on obtaining the Service Pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words: 3.50 nwlink nwnblink prodnt find name recognize
======================================================================
Keywords :
Technology : kbWinNTsearch kbWinNTWsearch kbWinNT350search kbWinNTW350 kbWinNTW350search kbWinNTSsearch kbWinNTS350 kbWinNTS350search kbAudDeveloper kbWFWSearch kbWFW311
Version : :3.11,3.5
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.