SYMPTOMS
========

Version 3.2x of the Microsoft Mail Gateway for X.400 may display the following
message in the X400xxxx.LOG file if verbose and debug logging are enabled
(-lvd):

  Incoming ER TPDU on connection xx:
  0970001A 00C10302 F080
  ERROR 1 (TRAN): Invalid TPDU 70 in state 4

CAUSE
=====

The data field in the message has a field length of zero. This is allowed if it
is the last packet.

RESOLUTION
==========

The remote X400 message transfer agent (MTA) must be able to accept the last
packet in the conversation if it has a data field length of zero. Contact the
administrator of the other X400 MTA to verify it will accept an end packet of
data field length zero.

MORE INFORMATION
================

A complete explanation of the TPDU follows:

  rv[ 10] 0970001A 00C10302 F080

     09  length       = 9
     70  TPDU type    = ER
     001A             = Destination reference
     00  reject cause = Not specified
     C1 03 02 F080    = The invalid TPDU that the other side is
                        complaining about.

The invalid TPDU:

     02 length        = 2
     F0 TPDU type     = DT
     80  EOT or the end flag.

The Microsoft X.400 Gateway may create a zero length data field if the length of
the message happened to fall on a DT TPDU boundary. This is not a violation of
the X.400 standard. According to X.224 section 6.3.3.:

  All DT TPDUs except the last DT TPDU in a sequence greater than one shall
  have a length of data greater than zero.

This is the last DT TPDU in a sequence (the EOT flag being on), so it is allowed
to have a zero length user data field.

Additional query words: x400 errmsg

======================================================================
Keywords          :  
Technology        : kbMailSearch kbMailGateSearch kbZNotKeyword3 kbMailGatex40032xSearch
Version           : MS-DOS:3.2x

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.