Q120757: WINS Manager: Config. and Replication Partners Menus Disabled
Article: Q120757
Product(s): Microsoft Windows NT
Version(s):
Operating System(s):
Keyword(s):
Last Modified: 08-AUG-2001
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Windows NT Workstation version 3.5
- Microsoft Windows NT Server version 3.5
-------------------------------------------------------------------------------
When using WINS Manager to administer a remote WINS server, you may notice
that all menu options are enabled except for the Configuration and
Replication Partners options of the Server menu.
Most WINS Manager commands are performed using IP-to-IP (non-NetBIOS)
connections. However, the Configuration and Replication Partners options
run over RPC which requires NetBIOS sessions (over TCP/IP) to be
established. If the NetBIOS connection fails, these two menu items will
appear disabled. Similarly, attempting to use Registry Editor to remotely
access the computer's Registry will fail because it also relies on an RPC
connection to be established. Once a NetBIOS connection is made, these
options are enabled.
To fix this problem:
1. Verify that you are a member of the Administrators or Domain Administrators
groups and that you are logged in with a proper password.
2. Verify that you are able to get a "Name to IP" resolution of the name of the
WINS server you are focused on:
a. From the Options menu choose Preferences. Try setting the address display
as "Computer Name (IP Address)" and/or "IP Address (Computer Name)" and
set the focus again on the remote WINS server by selecting it from the
list of WINS servers.
b. Use the IPCONFIG /ALL command to find the IP addresses of the primary and
secondary WINS servers you are consulting. Then enter the IP address and
name of the remote WINS server as a static mapping into the database of
the primary and secondary WINS servers you are consulting.
NOTE: Verify that all WINS servers are configured with static (not dynamic)
IP Addresses; they should not be DHCP clients.
Additional query words: grayed-out grey unavailable
======================================================================
Keywords :
Technology : kbWinNTsearch kbWinNTWsearch kbWinNT350search kbWinNTW350 kbWinNTW350search kbWinNTSsearch kbWinNTS350 kbWinNTS350search
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.