Q114285: BUG: Summary List of ODBC 1.0 Bugs

Article: Q114285
Product(s): Open Database Connectivity (ODBC)
Version(s): 1.0
Operating System(s): 
Keyword(s): 
Last Modified: 04-FEB-2002

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Open Database Connectivity, version 1.0 
-------------------------------------------------------------------------------

The following is a list of bugs confirmed in version 1.0 of Microsoft
Open Database Connectivity. This is not a comprehensive list; this list
is current as of March 1, 1994.

For more information on the bug listed, query in the Microsoft Knowledge
Base on the article ID or the bug number.

===========================

BUG LISTING FOR VERSION 1.0
---------------------------

- BUG: Oracle Driver Errors on Delimited Column Names

- BUG: Cannot Have a Pathname > 29 Char for SYSTEM.MDA

- BUG: Memory Leak in the ORACLE Driver

- BUG: Memory Leak in Desktop Database Drivers

- BUG: Access Driver Returns Incorrect pcbValue

- BUG: SQL Server SQLSetParam Fails on the 252nd Parameter

- BUG: Extra Block of 256 Bytes Used by Access ODBC Driver

- BUG: SQL Server ODBC Driver Removes Entry From WIN.INI

- BUG: Use of Certain Scalar Functions May Cause SQLFetch Errors

===================================

DESCRIPTION OF BUGS FOR VERSION 1.0
-----------------------------------

---------------------------------------------------

BUG: Oracle Driver Errors on Delimited Column Names
---------------------------------------------------

Article ID: Q104958
BUG# ODBCORA: 572 (1.002816)

SYMPTOMS
========

The Oracle ODBC Driver gives an error on any SELECT statement that contains an
outer join (in the ODBC escape-clause syntax) on a delimited column name that is
greater than 17 characters. As a result, when using Microsoft Access or
Microsoft Visual Basic to connect to an Oracle server, you cannot perform outer
joins on columns whose names are longer than 17 characters.

So, the following query:

  SELECT * FROM {oj table1 LEFT OUTER JOIN table2 ON
  (table1.abcdefghijklmnopq = table2.col1)}

works fine; note that the delimited column name (abcdefghijklmnopq) is 17 chars
long. However, the following query:

  SELECT * FROM {oj table1 LEFT OUTER JOIN table2 ON
  (table1.abcdefghijklmnopqr = table2.col1)}

gives the error:

  MsgId: Unknown String Resource.

The above error appears in a dialog box with an OK button. Choosing OK will cause
SQLExecDirect or SQLExecute to return SQL_ERROR. The SQL_ERROR states:

  szSqlState = "37000"
  [PageAhead][ODBC Oracle Driver]Syntax Error

While working with an ODBC Data source, the Access Engine uses delimited
identifiers for all its queries; it also uses canonical outer join syntax for
performing outer joins. Thus, when an Access or Visual Basic user does an outer
join on Oracle tables, the above mentioned error occurs if any of the columns
participating in the outer join have a name longer than 17 characters.

The ODBC Access driver does not recognize a SYSTEM.MDA file for which the path is
longer than 29 characters.

The ODBC Access driver can be used to connect to secure Access databases. To do
this, the user should specify a SYSTEM.MDA file associated with the Access
database--by selecting the Options button in the Access Datasource Setup dialog
box, and specifying a complete path for the SYSTEM.MDA file.

If this path is longer than 29 characters, the driver gives the following error
during SQLConnect or SQLDriverConnect:

  szSqlState = '08004', *pfNativeError = -1023
  szErrorMsg="[Microsoft][ODBC Single-Tier Driver][ODBC File
  Library]Invalid path

For example, the following path will work for SYSTEM.MDA (it is 29 characters
long):

  c:\temp\snuffy1\ok\system.mda

while the following does not work (it is 30 characters long):

  c:\temp\snuffy1\bad\system.mda

The ODBC Desktop Database Drivers have a memory leak due to which, a memory
allocation error occurs when a program repeatedly allocates and frees a
statement handle with the SQL_CLOSE option.

Allocating and freeing a statement handle (with fOption = SQL_CLOSE) repeatedly
will cause a memory allocation error in the 248th iteration. This problem exists
in all the drivers shipping with the ODBC Desktop Database Drivers (dBASE,
FoxPro, Paradox, BTRIEVE, Access, Excel and Text). The following code fragment
illustrates the problem:

  SQLAllocEnv(&henv);
  SQLAllocConnect (henv, &hdbc);
  SQLDriverConnect (hdbc, hwnd, "", 0, szConnStrOut, MAX_CONN_STR_SIZE,

  &cbConnStrOut, SQL_DRIVER_PROMPT);

  for (i=1; i<500; i++) {

  SQLAllocStmt(hdbc, &hstmt); SQLFreeStmt (hstmt, SQL_CLOSE);

  }

In the 248th iteration through the for loop, the following memory allocation
error occurs:

  SQLAllocStmt returned SQL_ERROR
  SQLSTATE = S1001, pfNativeError = [Microsoft][ODBC Single-Tier
  Driver]Memory allocation error

The ODBC Access driver returns incorrect pcbValue when a column with the ODBC SQL
type SQL_TIMESTAMP is converted to SQL_C_DATE via SQLBindCol or SQLGetData.

The following assumes that there is a table called DATETEST in which column
number 2 is a column of type datetime:

- SQLExecDirect the statement:

  select * from DATETEST

- Do a SQLBindCol on col #2 so that fCType is SQL_C_DATE.

- Do a SQLFetch.

- Examine the value of *pcbValue.

It will be 10; while the expected =6.

The same (invalid) pcbValue is returned if, instead of SQLBindCol, data is
retrieved through SQLGetData with fCType = SQL_C_DATE.

Correct pcbValue is returned when fCType = SQL_C_TIME.

--------------------------------------------------------

BUG: SQL Server SQLSetParam Fails on the 252nd Parameter
--------------------------------------------------------

Article ID: Q111723 BUG# ODBCSS: 2816 (1.01.2920)

The ODBC SQL Server driver returns an error with SQLSTATE S1093 when SQLSetParam
is called for the 252nd time on a prepared statement with more than 252
parameter markers in it.

Because of this, users of Microsoft Access version 1.1 may see an error,

  ODBC Call Failed

when they try and update an attached table with more than 125 columns.

--------------------------------------------------------

BUG: Extra Block of 256 Bytes Used by Access ODBC Driver
--------------------------------------------------------

Article ID: Q111724 BUG# ODBCDBASE: 2048 (1.01.1928)

The following sequence of calls,

  SQLAllocEnv, SQLAllocConnect, SQLConnect (or SQLDriverConnect),
  SQLDisconnect, SQLFreeConnect, and SQLFreeEnv

will cause an extra block of 256 bytes to be used by the application that made
the calls. This happens only with the Access ODBC Driver.

------------------------------------------------------

BUG: SQL Server ODBC Driver Removes Entry From WIN.INI
------------------------------------------------------

Article ID: Q112513 BUG# ODBCSS: 2834 (1.01.22807)

If an existing data source is reconfigured in such a way that only its name is
changed using either ODBC Administrator or ODBC icon from Control Panel for the
SQL Server driver, the corresponding server entry in the WIN.INI entry (for
non-default network or network library) is removed.

For example, assume a data source called MYSOURCE is configured and maps to a SQL
Server machine called SQLNT1. Also it is using dbmsspx3 Network Library
(Net-Library). So in the ODBC.INI file, the server entry for [MYSOURCE] would be
SQLNT1 and the corresponding entry in WIN.INI for this would be under SQL Server
section as follows:

  [SQL Server]
  SQLNT1=dbmsspx3,SQLNT1

Now if the data source name is changed from MYSOURCE to NEWSRC using ODBC
Administrator or ODBC icon in the control panel, the above entry for SQLNT1 will
be removed. This happens even though the server entry in ODBC.INI for the
[NEWSRC] still points to SQLNT1.

NOTE: In case of default network and Net-Library, no entry in needed in the
WIN.INI.

Under certain circumstances, memory allocation errors may be returned from
drivers that ship with the ODBC Database Driver Pack. These errors occur when
fetching a results set from a certain kind of SQL Statement that uses ODBC
scalar functions.

The following SQL query uses scalar functions and causes errors, not on
SQLExecDirect or SQLExecute, but on SQLFetch after 1087 rows have been
retrieved.

  select *
  from "test"
  where
  {fn CONVERT('19'+

  {fn LEFT("test"."col_DATE_Y" ,2) } + '-' + {fn LEFT("test"."col_DATE_MD",2)}
  + '-' + {fn RIGHT({ fn RTRIM("test"."col_DATE_MD") } , 2 ) }

  ,SQL_DATE)}
  >= '1992-01-01'

Errors received on SQLFetch after 1087 rows have been fetched:

  [Microsoft][ODBC Single-Tier Driver]Error in predicate:
  [Microsoft][ODBC Single-Tier Driver]Expression evaluation error
  [Microsoft][ODBC Single-Tier Driver]Memory allocation error.

WORKAROUND
==========

Rename the column so that it has less than 17 characters.

----------------------------------------------------

BUG: Cannot Have a Pathname > 29 Char for SYSTEM.MDA
----------------------------------------------------

Article ID: Q105795 BUG# ODBCDBASE: 1852 (1.01.1928)

Move the SYSTEM.MDA file to a different directory so that the path is less than
29 characters.

--------------------------------------------

BUG: Memory Leak in Desktop Database Drivers
--------------------------------------------


BUG# ODBCDBASE: 1850 (1.01.1928)

Use the following statement:

  fOption = SQL_DROP

instead of using the following in the SQLFreeStmt command:

  fOption = SQL_CLOSE

---------------------------------------------

BUG: Access Driver Returns Incorrect pcbValue
---------------------------------------------

Article ID: Q106480 BUG# ODBCDBASE: 1858 (1.01.1928)

Remove the data source and the add it back again. That will add the entry back in
WIN.INI.

--------------------------------------------------------------

BUG: Use of Certain Scalar Functions May Cause SQLFetch Errors
--------------------------------------------------------------

Article ID: Q112689 BUG# ODBCDBASE: 1857 (1.01.1928)

Additional query words:

======================================================================
Keywords          :  
Technology        : kbAudDeveloper kbODBCSearch kbODBC100
Version           : :1.0
Issue type        : kbbug

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.