KnowledgeBase Archive

An Archive of Early Microsoft KnowledgeBase Articles

View on GitHub

Q107996: WFWG 3.11: Real-Mode Redirector and Direct Hosting

Article: Q107996
Product(s): Microsoft Windows 3.x Retail Product
Version(s): WINDOWS:3.11
Operating System(s): 
Keyword(s): 
Last Modified: 30-SEP-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Windows for Workgroups version 3.11 
-------------------------------------------------------------------------------

SYMPTOMS
========

If Windows for Workgroups 3.11 has been configured to provide Novell NetWare
connectivity and you try to connect to a Windows for Workgroups 3.1, 3.11, or
Windows NT 3.1 server with the real-mode redirector, the following error may
occur:

  Error 53: The computer name specified in the network path cannot be located.

This error may occur when you run a NET USE or NET VIEW command with the Windows
for Workgroups 3.11 real-mode redirector. This error may also occur when you are
using the real-mode redirector even though no error occurs when you are
connected to the same servers from within Windows for Workgroups 3.11 while
using the protected-mode redirector.

CAUSE
=====

When Windows for Workgroups 3.11 is configured to provide Novell NetWare
connectivity, the real-mode redirector uses the IPX transport provided by the
Novell NetWare IPXODI driver.

A relationship called direct hosting is formed between the real-mode redirector
and the IPX transport. Direct hosting allows data to be transferred between
these two layers without requiring the presence of a NetBIOS interface.

Under this configuration, you cannot use the real-mode redirector to access a
server unless the server is running an IPX/SPX compatible transport.

RESOLUTION
==========

With this configuration, a Windows for Workgroups 3.11 server must be configured
to use the IPX/SPX Compatible Transport or IPX/SPX Compatible Transport with
NetBIOS to be accessible by the real-mode redirector.

There is no resolution available for a Windows NT server because the NWLink
IPX/SPX Compatible Transport provided with Windows NT requires a NetBIOS
interface that is not provided by the real-mode redirector in Windows for
Workgroups when a direct-hosting relationship exists.

MORE INFORMATION
================

When you are using Microsoft Windows for Workgroups 3.11 in a Novell NetWare
environment, you can install support for Novell NetWare connectivity in addition
to the Microsoft Windows Network.

To install support for Novell NetWare connectivity, select Novell NetWare
(Workstation Shell) as an additional network in the Networks dialog box of
Network Setup. This support also requires selecting one of the following drivers
from the Network Driver dialog box of Network Setup:

  IPXODI Support Driver (ArcNet)
  IPXODI Support Driver (Ethernet)
  IPXODI Support Driver (Token Ring)

This configuration allows Windows for Workgroups 3.11 to enable Novell NetWare
connectivity by interfacing with the IPX transport contained in the Novell
NetWare ODI drivers.

When you use this configuration with the Windows for Workgroups real-mode
redirector to connect to Windows for Workgroups servers, one of the following
protocol drivers should be selected in the Network Drivers dialog box of Network
Setup on the Windows for Workgroups server machine.

  IPX/SPX Compatible Transport

  -or-

  IPX/SPX Compatible Transport with NetBIOS

Installing one of these IPX/SPX compatible transports enables the real-mode
redirector to connect to the Windows for Workgroups server.

Additional query words: err msg 3.11

======================================================================
Keywords          :  
Technology        : kbAudDeveloper kbWFWSearch kbWFW311
Version           : WINDOWS:3.11

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.