Some laptop computers may experience problems associated with using Microsoft's
MS-DOS EMM386.EXE expanded memory manager.
MORE INFORMATION
================
EMM386.EXE allows MS-DOS to simulate expanded memory on computers with a 386 or
higher microprocessor. It also allows terminate-and-stay- resident (TSR)
programs and device drivers to be loaded into the upper memory area (UMA) to
free conventional memory for MS-DOS-based applications. You may experience
problems using EMM386.EXE on certain laptop computers.
Toshiba
-------
Symptoms
Toshiba has confirmed that EMM386.EXE, included with the Microsoft MS-DOS 6 and
6.2 Retail Upgrade Package, is not compatible with the Resume mode on Toshiba
laptops.
EMM386.EXE also disables the PopUp window on Toshiba laptops. If the EMM386.EXE
driver is loaded in the CONFIG.SYS file, the FN-PopUp key combination does not
cause the PopUp window to be displayed; therefore, you may be unable to view the
current battery charge or toggle the various battery options.
Resolution
For further information concerning installing MS-DOS 6.0 on Toshiba computers,
call Toshiba Technical Support at (800) 456-8649.
CompuAdd
--------
Symptoms
After running MEMMAKER.EXE or manually adding EMM386.EXE to the CONFIG.SYS file
on a CompuAdd 325TFX or 425TFX running LAP.SYS, the computer may stop responding
(hang) on startup.
Cause
This problem occurs because the LAP.SYS driver, which loads in the CONFIG.SYS
file, uses the upper memory address range C000-CFFF.
Resolution
To correct this problem, you must exclude the C000-CFFF range by adding the
parameter X=C000-CFFF to the EMM386.EXE line in the CONFIG.SYS file. For
example:
device=c:\dos\emm386.exe x=c000-cfff
LAP.SYS is CompuAdd's power management system program. For more information, call
CompuAdd Technical Support at (800) 999-9901.
Additional query words: 6.22 6.00 6.0 6 6.20 limulator hang hangs lockup compu add compu-add msdos ms dos power
======================================================================
Keywords : msdos
Technology : kbMSDOSSearch kbMSDOS621 kbMSDOS622 kbMSDOS620 kbMSDOS600
Version : MS-DOS:6.0,6.2,6.21,6.22
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.
Copyright Microsoft Corporation 1986-2002.