SYMPTOMS
========
LAN Manager servers receive an error 5325 (duplicate name found) or error 3172
(error sending alert message) along with error 2136 (Trap00D, Trap00C--general
network error). Primary server traps result in a ring0 error and complete loss
of functionality, although member servers also are trapped along with the
primary.
CAUSE
=====
Updated revision display level required.
RESOLUTION
==========
Update the display revision level from 1.02 files dated 10/1/90 to 1.03 dated
10/31/91 or later ones using the reference disk.
CONFIGURATION
-------------
The problem was reported on this configuration:
LAN Manager 2.2
OS/2 1.3
net card IBM 16 token ring
IBM model 95 486 server
HPFS386
user level security
NetBEUI.
Additional query words:
======================================================================
Keywords :
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.