KnowledgeBase Archive

An Archive of Early Microsoft KnowledgeBase Articles

View on GitHub

Q95396: WFWG Err Msg: Windows File Server… with SMC3000 Series

Article: Q95396
Product(s): Microsoft Windows 3.x Retail Product
Version(s): WINDOWS:3.1,3.11
Operating System(s): 
Keyword(s): 
Last Modified: 14-OCT-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Windows for Workgroups versions 3.1, 3.11 
-------------------------------------------------------------------------------

SYMPTOMS
========

If you use the Standard Microsystems Corporation (SMC) 3008 and 3016 Ethernet
network interface cards (NICs), the following error message may be displayed
when you start Windows for Workgroups or launch applications from Windows for
Workgroups:

  Windows File Server

  This application attempted to access a device that is being used by another
  application. If you continue running this application it may cause your
  system to lock up.

If you choose not to continue at this point, the system may stop responding
(hang). If you choose to continue, Windows for Workgroups may appear to function
normally. If you quit and then restart Windows for Workgroups, the system may
function and behave normally without generating the error.

WORKAROUND
==========

To eliminate the error message, use a text editor (such as Microsoft Windows
Notepad) to add one of the following lines to the [MS$SMC3K] section of the
PROTOCOL.INI file in the Windows directory:

  MICRO_CHANNEL=0 ; For ISA bus machines

  -or-

  MICRO_CHANNEL=1 ; For MCA bus machines

NOTE: You may need to change the MICRO_CHANNEL= setting to the opposite value of
the actual machine type (that is, for an MCA machine, choose ISA; for an ISA
machine, choose MCA).

MORE INFORMATION
================

The setting MICRO_CHANNEL=0 informs the Protocol Manager that the computer is an
ISA bus machine and that all network card settings should be retrieved from the
PROTOCOL.INI file. The setting MICRO_CHANNEL=1 informs the Protocol Manager that
the computer is an MCA bus machine and that all network card settings should be
read from the network card itself.


The SMC 3000 Series network interface cards are manufactured by Standard
Microsystems Corporation, a vendor independent of Microsoft; we make no
warranty, implied or otherwise, regarding these products' performance or
reliability.

Additional query words: 3.10 3.11 err msg 3rdparty

======================================================================
Keywords          :  
Technology        : kbAudDeveloper kbWFWSearch kbWFW310 kbWFW311
Version           : WINDOWS:3.1,3.11

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.