SYMPTOMS
========

After upgrading to Windows for Workgroups (WFWG) from Windows version 3.0 or 3.1
with version 6.x of CO/Session installed, the following error message occurs
when you try to run Windows for Workgroups in enhanced mode:

  A device has been specified more than once in the SYSTEM.INI file or a device
  specified in SYSTEM.INI conflicts with a device which is being loaded by an
  MS-DOS device driver or application. Remove the duplicate entry from the
  SYSTEM.INI file and restart Windows.

CAUSE
=====

Both CO/Session and Windows for Workgroups install a virtual communications
driver (VxD). When Windows for Workgroups upgrades, it places a second VxD in
the [386Enh] section of the SYSTEM.INI file. Even though these drivers have
different filenames, Windows for Workgroups sees them as duplicates because they
are both virtual communications drivers.

CO/Session originally adds:

      DEVICE=CS$VCD.386

Windows for Workgroups upgrade then adds:

      DEVICE=VCD.386

WORKAROUND
==========

1. Edit the SYSTEM.INI file with any text editor.

2. Locate the [386Enh] section and find lines similar to the following:

        DEVICE=CS$VCD.386
        DEVICE=VCD.386

  NOTE: The line may read DEVICE=VCD$CS.386

3. To enable the default Windows for Workgroups driver, insert a semicolon (;)
  at the beginning of the DEVICE=CS$VCD.386 line, as follows:

        ;DEVICE=CS$VCD.386

4. To enable the CO/Session driver, insert a semicolon (;) at the beginning of
  the DEVICE=VCD.386 line:

        ;DEVICE=VCD.386


MORE INFORMATION
================

For additional information concerning functionality of CO/Session and Windows
for Workgroups, contact Triton Technologies, Inc.

CO/Session is manufactured by Triton Technologies, a vendor independent of
Microsoft; we make no warranty, implied or otherwise, regarding this product's
performance or reliability.

Additional query words: 3.10 3.1

======================================================================
Keywords          :  
Technology        : kbAudDeveloper kbWFWSearch kbWFW310
Version           : WINDOWS:3.1

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.