Q89515: LAN Man 2.1 Test Summary (DigiBoard DigiCHANNEL C/X EISA)

Article: Q89515
Product(s): Microsoft LAN Manager
Version(s): 
Operating System(s): 
Keyword(s): 
Last Modified: 30-JUL-2001

SUMMARY
=======

The following are the test results for the DigiBoard DigiCHANNEL C/X System,
EISA Host Adapter multiport communication board. The test was conducted as part
of the Microsoft Compatibility Lab (MCL) peripheral test for LAN Manager version
2.1:

MORE INFORMATION
================

Company
-------

DigiBoard
6751 Oxford St.
Minneapolis, MN 55426
(612) 943-9020

Date Tested
-----------

5/19/92

Multiport Communication Board
-----------------------------

Model:                 DigiCHANNEL C/X System, EISA Host Adapter
Serial number:         473672
I/O port:              N/A
Memory address:        0D0000h

Board Switch Settings
---------------------

No switches to set on this board.

Other Hardware Supplied
-----------------------

Connector for port board:        DIGICHANNEL C/CON - 16 (DB25)
Part number:                     50000043 REV.F

Software and Drivers
--------------------

OS/2 device driver filename:     XALL.SYS
Date of file:                    11/20/91
Version:                         1.3.2

Line Added to CONFIG.SYS
------------------------

device=c:\digi\xall.sys /a:Q /n:3 /p:5005 /m:D0000 /t:m10

Testing Environment
-------------------

Operating system:        OS/2 1.3
Network:                 LAN Manager 2.1
Test platforms:          486/33 16 MB RAM
Bus specification:       EISA
Network topology:        Ethernet
Server file system:      HPFS

Final Test Results
------------------

Test Focus                    Pass    Anomalies and/or Workarounds
----------                    ----    ----------------------------
Installation                   Yes    The server and all RAS clients
                                     are using a null modem Cable
                                     running at 9600 baud. Higher
                                     baud rates are available using
                                     the DigiBoard, but are not
                                     recommended for the RAS service.

Remote Access admin            Yes
Remote Access server           Yes
Network functionality          Yes
Stress                         Yes
Named pipes                    Yes

Additional query words: certification 2.1 2.10

======================================================================
Keywords          :  

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.