KnowledgeBase Archive

An Archive of Early Microsoft KnowledgeBase Articles

View on GitHub

Q89081: WFWG Err Msg: No Files Found… Using CD-ROM and NetWare

Article: Q89081
Product(s): Microsoft Windows 3.x Retail Product
Version(s): WINDOWS:3.1,3.11
Operating System(s): 
Keyword(s): 
Last Modified: 06-OCT-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Windows for Workgroups versions 3.1, 3.11 
-------------------------------------------------------------------------------

SYMPTOMS
========

Either of the following error messages may appear in Windows for Workgroups when
you attempt to access a shared CD-ROM drive in File Manager

- No files found

  -or-

- Error Reading Drive <x>

where <x> is the next logical drive.

CAUSE
=====

This occurs if MSIPX.COM, VLM.EXE, NETX.COM, or NETX.EXE are loaded before
MSCDEX.EXE or if the /S parameter is not used with MSCDEX.EXE in the
AUTOEXEC.BAT file on the computer sharing the CD-ROM.

MORE INFORMATION
================

To allow Novell NetWare connectivity with Windows for Workgroups, MSIPX.COM
VLM.EXE, NETX.COM, and NETX.EXE may be placed in the AUTOEXEC.BAT file. If these
files appear before the CD-ROM driver MSCDEX.EXE, the error message appears when
the CD-ROM is a shared resource and is being accessed remotely. The server that
is sharing the CD-ROM has access to files, but any attempt by users to access
files on the CD-ROM results in the error.

To correct the problem, edit the AUTOEXEC.BAT and file on the server and move the
MSCDEX.EXE command above the other entries listed above. You may also need to
edit the CONFIG.SYS so that the CD-ROM driver is the first driver listed.

The error may also appear if the server is not sharing the CD-ROM properly. To
share the CD-ROM, the /S parameter must be used with MSCDEX.EXE. Under Windows
3.1, LANMAN10.386 was needed for enhanced mode functionality of the CD-ROM. In
Windows for Workgroups, this functionality is inherent and LANMAN10.386 is not
needed.

If the line

       device=LANMAN10.386

exists in the [386Enh] section of the SYSTEM.INI file, you should remove it and
add the /S parameter to MSCDEX.EXE

Additional query words: 3.10 3.11 ipx ms 3rdparty

======================================================================
Keywords          :  
Technology        : kbAudDeveloper kbWFWSearch kbWFW310 kbWFW311
Version           : WINDOWS:3.1,3.11

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.