KnowledgeBase Archive

An Archive of Early Microsoft KnowledgeBase Articles

View on GitHub

Q87134: Setting Up a 3Station to Remote Boot

Article: Q87134
Product(s): Microsoft LAN Manager
Version(s): 
Operating System(s): 
Keyword(s): 
Last Modified: 30-JUL-2001

SUMMARY
=======

Microsoft supports LAN Manager on 3Com 3Server 400/500/600 models. Other models
use an 80186 and cannot be configured as LAN Manager servers. Both LAN Manager
versions 2.0 and 2.1 should run equally well on all three types of machines. The
LAN Manager 2.0 Value Pack does not provide any documentation on RIPL, and
therefore is not a supported service for the 3Server.

In LAN Manager 2.1, 3Com 3Station support is provided with the standard remote
boot features. See Chapter 13 in the "Microsoft LAN Manager Administrator's
Guide" for details on setup and possible problems.

It is not necessary to create a special profile for the 3Station; just use the
"DOS 5.00 Default" option from the RPL Manager drop menu selections, which
appear as follows:

  ===>  DOS 5.00 Default
        DOS 5.00 3Com Etherlink
        DOS 5.00 3Com Etherlink II
        DOS 5.00 3Com Etherlink Plus
        DOS 5.00 3Com Etherlink MC
        DOS 5.00 IBM Ethernet
        DOS 5.00 NOVELL NE 2000

The DOS 5.00 Default profile option for the 3Station should cause it to start up
correctly. If there are problems, you may have to manually edit the RPL.MAP file
in the \LANMAN\RPL directory to change the acknowledge setting for 3Stations.

Use an editor to search for the text string "3Station" in the RPL.MAP file. This
should bring you to line 59, which should appear as follows:

  yyyyyyyyyyyy BBLOCK\NETBEUI\E3STAT\DOSBB.CNF 2 6 F ~ DOS~3Com~3Station
...

Change line 59 to appear as follows:

  yyyyyyyyyyyy BBLOCK\NETBEUI\E3STAT\DOSBB.CNF 2 6 A ~ DOS~3Com~3Station

...

                                                   ^
                                                   |
                                             Change is here

This should eliminate problems with packet acknowledgement.

Other issues to consider when troubleshooting a 3Station are as follows:

- Check the net address of the 3Station. It should begin with 02608C in order
  to be recognized by the DOS 5.00 Default profile.

- 3Com 3Stations with new PROMs will have addresses out of the 20608C range and
  will therefore require a change to the RPL.MAP to reflect use of the newer
  PROM.

- Make sure the two hidden system files are in the MS-DOS 5.0 directory.

- Make sure the system file attributes are removed (no hidden or system
  attribute).

- Make sure 3Start is not running on the local net. 3Start assumes that no
  other RPL server is on the local area network and will respond to all START
  requests. Because 3Start and LAN Manager RPL use the same socket, RPL will
  also try to respond to the request.

- Make sure the 3Station is set up to use the correct transceiver. Press
  CTRL+ALT+SHIFT+DEL to access the Setup program.

Additional query words: 2.00 2.10 LM2.1 RPL

======================================================================
Keywords          :  

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.