KnowledgeBase Archive

An Archive of Early Microsoft KnowledgeBase Articles

View on GitHub

Q86248: Incorrect CMOS Setting May Cause Insufficient Memory Error

Article: Q86248
Product(s): Microsoft Windows 95.x Retail Product
Version(s): WINDOWS:3.1,3.11
Operating System(s): 
Keyword(s): 
Last Modified: 25-SEP-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Windows versions 3.1, 3.11 
-------------------------------------------------------------------------------

SYMPTOMS
========

The following error message may appear in Windows 3.1 when you try to run a
program from a floppy disk drive:

  Insufficient memory to run application; close one or more applications to
  increase available memory and try again.

RESOLUTION
==========

Verify that the CMOS settings for the floppy disk drive are correct. If the
drive is set incorrectly (for example, you select 720K when the drive is a
1.44MB), selecting the correct setting should correct the problem.


MORE INFORMATION
================

When you run an application from the floppy disk drive by choosing Run from the
File menu in Program Manager, the above error message may occur if the drive is
incorrectly configured.

An incorrect CMOS floppy disk drive setting may also display the following
message:

  Cannot find file <X>:<FILENAME> (or one of its components). Check
  to ensure the path and filename are correct and that all required libraries
  are available.

where <X> is the floppy disk drive letter and <FILENAME> is the name
of the program being loaded.

When you attempt to install an application from the floppy disk drive, the
following message may be displayed:

  Not enough memory to start the specified application.

Additional query words: 3.10 errmsg

======================================================================
Keywords          :  
Technology        : kbWin3xSearch kbZNotKeyword3 kbWin310 kbWin311
Version           : WINDOWS:3.1,3.11

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.