This article applies to LAN Manager versions 2.0, 2.1, 2.1a, and 2.2 running
under OS/2 versions 1.2 and 1.3 or MS-DOS version 5.0.
SYMPTOMS
========
3Com ELNK16 adapters are not jumper-configurable. Instead, they contain an
EEPROM that stores configuration information. You set up the interrupt, I/O base
address, transceiver type, and so on by running the 3Com 3c507 Setup program.
Because the card doesn't contain jumpers to set the I/O base, the ELNK16 uses
I/O base 100 as a reference point during start-up and diagnostics. Once the
driver is activated (at binding), it uses the configuration settings stored in
the EEPROM.
When the computer starts up, both ELNK16 cards use I/O base 100 as a reference
point. Because the ELNK16 is ROM configurable, there is no way for the driver to
know which adapter is being bound. Thus, the following messages may appear upon
rebooting (an OS/2 machine):
HPFS File system driver is installed MS OS/2 Lan Manager Protocol V1.1 3Com
OS/2 Network Driver for the Etherlink16 (3C507) V1.1 3Com OS/2 Network Driver
for the Etherlink16 (3C507) V1.1 Microsoft OS/2 NetBEUI 2.0 Installing
NETWKSTA.SYS Ver2.0.292 (May 25, 1991)
PRO003: INTERRUPT CONFLICT in binding NETBEUI to ELNK16_NIF2 SYS1719: The file
"C:\LANMAN\NETPROG\NETWKSTA.SYS" specified in the IFS command on line 46 of
the CONFIG.SYS file does not contain a valid device driver or file system
driver.
CAUSE
=====
Normally, jumpers and the IOADDRESS= parameter in PROTOCOL.INI differentiate
adapters from one another so the drivers know where to look for the board. In
the case of the ELNK16 adapters, the IOBASE= parameter must be put under the
DRIVERNAME=ELNK16$ (and ELNK16x$) in PROTOCOL.INI so the driver can find the
appropriate address to bind. Leaving out this parameter generates the above
interrupt conflict message, even though there may appear to be no conflict with
the interrupt.
MORE INFORMATION
================
Listed below is a sample configuration, tested on a Compaq 386/33 with LAN
Manager 2.0c and OS/2 1.3, running NETBEUI protocol:
Card Configurations
-------------------
Card 1 Settings Card 2 Settings
--------------- ---------------
I/O base address: 300 Hex 320 Hex
Interrupt level: 10 12
Transceiver type: ON-Board ON-Board
RAM base address: C0000 Hex D0000 Hex
RAM size: 64 KB 64 KB
ROM base address: DA000 Hex DE000 Hex
ROM size: 00 KB 00 KB
Zero wait state: DISABLE DISABLE
Data mode: TURBO TURBO
CONFIG.SYS, LANMAN Section
--------------------------
REM ===== LANMAN 2.0 === DO NOT MODIFY BETWEEN THESE LINES ==== LANMAN
DEVICE=C:\LANMAN\DRIVERS\PROTMAN\PROTMAN.OS2 /i:C:\LANMAN
DEVICE=C:\LANMAN\DRIVERS\ETHERNET\ELNK16\ELNK16.OS2
DEVICE=C:\LANMAN\DRIVERS\ETHERNET\ELNK16\ELNK16.OS2
DEVICE=C:\LANMAN\DRIVERS\PROTOCOL\NETBEUI\NETBEUI.OS2
DEVICE=C:\LANMAN\NETPROG\RDRHELP.SYS
IFS=C:\LANMAN\NETPROG\NETWKSTA.SYS /i:C:\LANMAN
REM ===== LANMAN 2.0 === DO NOT MODIFY BETWEEN THESE LINES ==== LANMAN
PROTOCOL.INI
------------
[PROTOCOL MANAGER]
DRIVERNAME = PROTMAN$
[NETBEUI_XIF]
DRIVERNAME = NETBEUI$
BINDINGS = "ELNK16_NIF","ELNK16_NIF2"
[ELNK16_NIF]
; protocol.ini section for 3Com Etherlink16 and Etherlink16 TP Adapter card
DRIVERNAME = ELNK16$
IOBASE = 0x300
[ELNK16_NIF2]
DRIVERNAME = ELNK16X$
IOBASE = 0x320
LANMAN.INI
----------
In [NETWORKS] section:
net1 = netbeui$,0
net2 = netbeui$,1
In [WORKSTATION] section:
wrknets = net1,net2
In [SERVER] section:
srvnets = net1,net2
Notes
-----
1. Any ISA adapter that uses an EEPROM to store settings will operate in a
similar manner.
2. NetBEUI is not a routable protocol. As a result, nodes attached to the two
network segments connected to the server can communicate with the server, but
cannot exchange information between themselves.
Additional query words: 2.00 2.10 2.10a 2.20 1.20 1.30 5.00 etherlink16 bind conflict
======================================================================
Keywords : kbnetwork
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.