Q73293: When MS-DOS Fails to Load in the HMA
Article: Q73293
Product(s): Microsoft Disk Operating System
Version(s): MS-DOS:5.0,5.0a,6.0,6.2,6.21,6.22
Operating System(s):
Keyword(s):
Last Modified: 19-NOV-1999
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft MS-DOS operating system versions 5.0, 5.0a, 6.0, 6.2, 6.21, 6.22
-------------------------------------------------------------------------------
SUMMARY
=======
MS-DOS version 5.0 and 6.0 can save memory by loading itself into the first 64K
of extended memory, the high memory area (HMA). To check whether MS-DOS has
loaded itself in the HMA, issue the MEM command and look at the output. If the
last line of output reads
MS-DOS is resident in High Memory Area
then MS-DOS has loaded itself into the HMA. However, if MS-DOS has failed to load
into the HMA, you will get one of two messages:
64Kb High Memory Area is Available
-or-
High Memory Area is in Use
MORE INFORMATION
================
The first message, "64Kb High Memory Area is Available," is usually caused by
not having the following line in the CONFIG.SYS file:
DOS=HIGH
To correct this problem, add the "DOS=HIGH" (without the quotation marks) line to
CONFIG.SYS.
The second message, "High Memory Area is in Use," has two possible causes:
- Something else is being loaded into the HMA, such as a network driver or some
other application. If you want to run MS-DOS in the HMA instead of the
program that is currently using it, you must disable the ability of the other
program to use the HMA. Consult that program's documentation for the disable
procedure. Then, you will need to add the line "DOS=HIGH" (without the
quotation marks) to your CONFIG.SYS file and ensure that you are loading
HIMEM.SYS.
- HIMEM.SYS is using the incorrect A20 handler. Upon installation, HIMEM.SYS
usually selects one of 16 different A20 handlers, depending upon the hardware
it detects. HIMEM's automatic detection can be overridden by the /MACHINE: or
/M: switch. If HIMEM.SYS is installing the wrong A20 handler on its own, you
must force it to install the correct handler with the /MACHINE: switch.
However, if HIMEM.SYS is being forced to install an incorrect A20 handler by
the /MACHINE: switch, you may be able to solve the problem by removing the
/MACHINE: switch and allowing HIMEM to select which A20 it uses.
For more information on MS-DOS 5.0's HIMEM.SYS and the /MACHINE: switch, see
pages 610-613 of the version 5.0 "Microsoft MS-DOS User's Guide and
Reference," or query on the following words:
" HIMEM and /M and MS-DOS " (without the quotation marks)
If you are using MS-DOS 6.x, type "help himem.sys" (without the quotation
marks) at the MS-DOS command prompt, and then press ENTER.
Additional query words: 6.22 5.00 5.00a 6.00 6.20
======================================================================
Keywords :
Technology : kbMSDOSSearch kbMSDOS621 kbMSDOS622 kbMSDOS620 kbMSDOS600 kbMSDOS500 kbMSDOS500a
Version : MS-DOS:5.0,5.0a,6.0,6.2,6.21,6.22
=============================================================================
THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.
Copyright Microsoft Corporation 1986-2002.