SUMMARY
=======

When running Windows 3.0 in real or standard mode, or Windows 3.1 in standard
mode, the following warning message appears in a dialog box when you run any
Windows communications program and attempt to start an MS-DOS application (or
vice versa):

The title bar of the error message display the name of the MS-DOS application,
then in the error message box it displayS the following:

  Another application is using the communication port. It might lose characters
  if you decide to start your application now.

  Do you want to start your application? Y/N

MORE INFORMATION
================

This warning message appears when you start an MS-DOS application while running
a Windows communication program that uses the communication (COM) ports. The
active communication program in Windows may lose data or its connection if the
MS-DOS application uses the same port during its current session.

To avoid this, do one of the following:

- Exit the Windows communications program and then start the MS-DOS
  application.

  -or-

- In the Windows communications program, set the port connection to none.

NOTE: Even if a PIF file is used for the MS-DOS application where no COM port is
chosen to modify, the warning message is still displayed because the Windows
communications program is currently using the port.

This problem does not occur in 386 enhanced-mode Windows because the programs are
multitasking and the COM ports are virtualized. In standard and real mode, the
Windows communication programs are suspended in memory until reactivated.

This problem has been tested with the following Windows communication programs:

- Windows 3.0 Terminal Program

- Dynacomm

Additional query words: 3.0 3.00 3.1 3.10 3.11 wincomm

======================================================================
Keywords          :  
Technology        : kbWin3xSearch kbZNotKeyword3 kbWin300 kbWin300a kbWin310 kbWin311
Version           : WINDOWS:3.0,3.0a,3.1,3.11

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Copyright Microsoft Corporation 1986-2002.