Q67656: Zenith ZBF-3339-EK 16 MHz 386 Conflict w/ Server Services

Article: Q67656
Product(s): Microsoft LAN Manager
Version(s): 
Operating System(s): 
Keyword(s): 
Last Modified: 30-JUL-2001

SYMPTOMS
========

Failure to complete a NET START NETLOGON command, with general network failure
error 2136 indicates a hardware conflict. In one reported case, the system
included a WD8003E Ethercard Plus card and the MACWD.OS2 driver, configured
correctly.

CAUSE
=====

Although the interrupts were correct, something still conflicted with OS/2 LAN
Manager.

RESOLUTION
==========

NET START NETLOGON completed successfully when these changes were made:

- INT to 5

- Mem to D1000

- IOAddress to 300

Note: Because this problem was due to a hardware conflict, Error 2136 could have
been generated by any number of other server service commands (for example,
REPLICATOR).

Additional query words: 2.00 2.0 2.10 2.1 2.10a 2.1a 2.20 2.2

======================================================================
Keywords          :  

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.