KnowledgeBase Archive

An Archive of Early Microsoft KnowledgeBase Articles

View on GitHub

Article: Q66789
Product(s): Microsoft LAN Manager
Version(s): 
Operating System(s): 
Keyword(s): 
Last Modified: 30-JUL-2001

SUMMARY
=======

Question:

  I tried to run Windows version 3.0 or 3.1 in 386 enhanced mode while using a
  3Com EtherLink Plus card. Unfortunately, Windows hung and I had to reboot my
  machine. How can I prevent Windows from hanging?

Response:

  On some systems, the 3Com EtherLink Plus card should not be allowed to
  control DMA transfers when running Windows version 3.0 or 3.1 in 386 enhanced
  mode. The following method can be used to disable the card's control of the
  DMA by adding one of the following lines to the [ELNKPL_NIF] section of the
  DOS LAN Manager version 2.0 (or later) PROTOCOL.INI file:

     ; Use this line if the card is in a 16-bit slot.
        DATATRANSFER = PIO_WORD

     ; Use this line if the card is in an 8-bit slot.
        DATATRANSFER = PIO_BYTE

Additional query words: 2.00 2.10 2.10a 2.20 3.00 3.10

======================================================================
Keywords          :  

=============================================================================

THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.